Specifications
6
Fitting the Flue Shield Deflector
for Tarras MKII and Flare (All Variants)
To fit the heat shield deflector:
Place the deflector on top of the
heat shield and ensure no large
gaps
Fix in place by securing the tabs
with rivets to the heat shield
150mm Diameter Flue
Flue Shield Deflector
Flue Shield
Standard 900mm high flue shield:
ECR & RMF
Standard 1200mm high flue shield:
Brunner, Tasman, Aspen & Strongman
1200mm high flue shield with flue shield deflector (REQUIRED)
Tarras MKII & Flare (All Variants) - See Below
*IMPORTANT - Flue shields should be no further than 10mm off the top of the fire box*
Factory Flue Shields
All Woodsman free standing fires have been tested and approved to ASNZ 2918:2001
with a ceiling height of 2.4m and with the factory flue shield fitted in the below configu-
rations. In some cases, the top of the flue shield terminates within 600mm of the ceiling
height (refer to ASNZ 2918:2001 4.5.2) but all ceiling temperatures did not exceed the
allowable limit in these cases and are therefore able to be installed. Reports are avail-
able on request for Councils.
If the ceiling height is less than 2.4m, then heat shielding is required as per ASNZ
2918:2001 Table 3.2
Ceiling Heights
WARNING
This part is required to be installed on
the listed models with ALL types of flue
kits. Failure to do so, may cause the
ceiling to over heat. The part is located
in the fire itself and not the flue kit
packaging.