When the water temperature is eual to or higher than the target temperature, start cooling when the water
temperature is eual to or less than the target temperature , start heating
F02
When the displayed temperature deviates from the actual temperature, this function can be used for calibration.
F03
When there is a deviation between the inlet water temperature and the displayed water temperature, you can
use this function to correct it. When you click on the correction, a pop-up prompt will appear to confirm the
current temperature and then enter the correction numeric keyboard pop-up window.
F04
After clicking on, there will be a 3-minute countdown. If the water pump does not report an error, the
compressor and fan will be started.
F0
Click setting and you will be prompted to enter the password to enter the settings.
F06
Defrost operation, and it will eit defrost when the time is over
F0
Defrost will be eecuted when the continuous operation time of
electric heating reaches the factory setting
F08
Set to 0 Celsius mode set to 1 Fahrenheit mode
F09
imit the maimum value of the target temperature, when the temperature eceeds this set value, the
over-temperature protection will be triggered.
F10
imit the lowest value of the target temperature, when the temperature is lower than this setting, the ultra-low
temperature protection will be triggered.
F11
The current eceeds this setting value and will triggers overload protection when the compressor is working .
F12
If the compressor of working current overload duration is greater than this setting value, then will trigger this
protection.
F13
Set to 0 to display the internal temperature of the evaporator to 1 to display the water inlet temperature
F14
After press the Oone button , it will start counting down according to this setting time. When the countdown
ends, it will stop the Oone to continue working.
F1
The current of the fan eceeds this setting value when the fan is working then will triggers the overload
protection
F16
The current is lower than this setting value when the water pump is working and then will triggers the overload
protection.The monitoring starts after minutes of power on.
F1-01
The water pump is stuck and there is no water flow
F1-02
The water pump is running normally and the water flow is small
F1-03
The water pump is running normally but no water flow in the waterway
F18
Detect the refrigerant pressure of the chiller system through a pressure switch
F19
The absolute value of the subtraction between the monitored inlet water temperature and the monitored
evaporator internal temperature
F20
Set to 0 All detection function device will invalid. Set to 1 All detection function device will be valid
F21
Automatic screen save time
Parameter annota�on