VERY IMPORTANT!
WOOD STONE RECOMMENDS THAT YOU SUBMIT YOUR
VENTING PLANS TO LOCAL CODE AUTHORITIES
BEFORE PROCEEDING WITH INSTALLATION.
It is never appropriate to use “B vent” in any part of an exhaust system
connected to a Wood Stone oven.
All ducting material must be
manufactured to the specifications of a grease duct. Due to the possibility
of sparks entering the duct, exhaust systems serving solid-fuel
equipment SHOULD NOT be combined with exhaust systems serving
other (non-solid-fuel) equipment.
OVEN VENTING (continued)
Views of installation of a Wood Stone hood. Note that the notch of the hood is even with
the front edge of the oven. Hood may be moved forward slightly if needed. The hood
should be installed in accordance with the hood manufacturer's instructions, and with
NFPA 96 and/or the applicable local and national codes.
Allow 8"min. opening
between any facade
and the inside edge
of the front of the
hood to allow for filter
removal.
8"
3. Exhaust from Wood Stone Wood/Gas combination ovens may be combined with exhaust
from other solid-fuel equipment ONLY, provided that duct meets the requirements listed in #1.