Technical data
Mountain Series CE 
Installation and Operation Manual
6
An ongoing program of product improvement may require us to change
specifications without notice. WS-MS-(RFG, RFG-IR)-CE,
Revised May 2014 Doc no: M0037.01
info@woodstone-corp.com or visit woodstone-corp.com
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t. +1.360.650.1111
f. +1.360.650.1166
INSTALLATION CLEARANCES
CLEARANCES
a.  Wood Stone gas-fired oven should have a minimum 25 mm (1") clearance to combustibles from all sides, and 
356 mm clearance to combustibles from the top� If building a facade that will contact the oven, use completely non-
combustible materials*� Please note that standard Drywall (or Sheetrock) is considered a combustible� Stucco equipped 
ovens must have a minimum 25 mm (1") thick application of non-combustible stucco cement applied to the body of the 
oven�
b.  Any facade materials 152 mm (6") to either side of the oven doorway and above must be constructed of non-combustible 
building materials�
c.  Install this oven only on noncombustible floors�
* When noncombustible building materials contact the body of the oven, the respective clearances are transferred to those non-
combustibles�
IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THESE 
INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED 
CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT THIS OVEN BE 
INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
!
WARNING: Installation and servicing of this product could expose you to glasswool/ceramic 
fibers as well as calcium silicate dust. ALWAYS WEAR RESPIRATORY AND EYE PROTECTION 
WHEN INSTALLING OR SERVICING THIS APPLIANCE. Please read this entire manual before 
you install the oven. Failure to follow instructions may result in property damage, bodily 
injury or even death. Contact your local building or fire officials about restrictions and 
installation inspection in your area.
INSTALLATION CLEARANCES