VENTING DO’S AND DONT’S
HOOD INSTALLATION WITH DECORATIVE FACADE WALL/OVEN ENCLOSURE
For installations where a hood is being used with a decorative facade wall or oven enclosure, it will be necessary to both seal the 
gap between the facade wall and the top of the oven, and the gaps at the sides of the hood between the facade wall and the front 
of the oven� This will prevent air from being pulled up the sides of the oven from below by the hood� It will also prevent debris, etc� 
from falling into the facade wall�
Note that the hood does extend out beyond the face of the 
oven� DO NOT extend the oven facade wall into the oven 
hood� The wall beneath the hood must stop at the top of the 
oven� To allow for proper function of the hood, filter removal 
and hood maintenance you must provide a minimum of 
203mm (8") of clearance between the front face of the 
facade wall and the front of the hood� 
Additional flashing detail
Continued on next page
Wall stud
Shield 
flashing 
to be 
flush 
with 
top of 
oven
Flashing piece 
by installer
Acceptable venting
Acceptable venting