OVEN VENTING
Wood Stone ovens should be vented in accordance with pertinent national, regional and local codes concerning such appliances;
check venting plans with the authority having jurisdiction before proceeding with installation�
The above statement taking precedence, Wood Stone Corporation recommends the following two venting options:
1.
The Wood Stone MS Series ovens can be vented as a Type A appliance (with no flue connection), designed to be installed
under an exhaust hood (canopy)� The hood must be a Type 1 (grease rated) hood connected to a (grease rated) duct system�
The venting system must be designed and installed in accordance with all relevant codes pertaining to grease and smoke
producing commercial cooking appliances� Ovens that utilize solid fuel must be vented separately from any non-solid fuel
burning appliances� There may be requirements for interlocking the oven or its gas supply with the ventilation system� Check
with your local code official� Airflow should be adjusted according to the requirements specified by the hood manufacturer
and/or local codes�
OR
2. The oven is also approved as a Type B
11
appliance, designed to be connected directly to a chimney which is installed in
accordance with all relevant local and national codes� The chimney system must be installed and constructed to the same
requirements as a duct that serves grease and smoke producing commercial cooking appliances� If venting the oven with this
method, the oven must be vented independently of other equipment� A suitable fan should be used at the end of the duct run
to ensure proper draft in all conditions� Wood Stone does not recommend using an in-line type fan� When installed, the fan
speed/air flow should be adjusted to attain the appropriate duct pressure at the oven flue collar:
DUCT PRESSURE
For gas-fired ovens without solid fuel: 0�25 mbar, (0�1" W�C�)
For any oven utilizing solid fuel: 0�35 mbar, (0�14" W�C�)
This pressure may be checked by inserting the pressure test probe up through the oven doorway to the point where the
duct is connected to the oven flue collar
FAN TEMPERATURE RATING
The fan must also be of a suitable temperature rating�
For gas-fired ovens without solid fuel the fan must be rated for a minimum of 150 °C (300 °F) continuous�
INTERLOCK SYSTEM
There may be requirements for interlocking the oven or its gas supply with the ventilation system� Check with your local
code official�