STUCCO APPLICATION
STUCCO APPLICATION
This figure depicts the 
application of stucco on a 
Wood Stone appliance�
Use no less than 25 mm (1") 
of stucco coating to cover all 
exposed metal lathing on the 
appliance�
Maintain a minimum of 152 
mm (6") clearance from 
top and 25 mm (1") from 
side of the appliance to all 
combustible surfaces. 
TRADITIONAL
STUCCO MIX
1 part masonry cement 
1 part regular cement
5 parts sand
Stucco premix is available 
at your local lumber yard or 
building supply store�
Follow stucco manufacturer’s 
instructions for correct mixing 
information�
MINIMUM STUCCO 
APPLICATION IS 25 mm 
(1")