Technical data

Mountain Series CE
Installation and Operation Manual
13
An ongoing program of product improvement may require us to change
specifications without notice. WS-MS-(RFG, RFG-IR)-CE,
Revised May 2014 Doc no: M0037.01
info@woodstone-corp.com or visit woodstone-corp.com
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
t. +1.360.650.1111
f. +1.360.650.1166
STUCCO APPLICATION
STUCCO APPLICATION
This figure depicts the
application of stucco on a
Wood Stone appliance�
Use no less than 25 mm (1")
of stucco coating to cover all
exposed metal lathing on the
appliance�
Maintain a minimum of 152
mm (6") clearance from
top and 25 mm (1") from
side of the appliance to all
combustible surfaces.
TRADITIONAL
STUCCO MIX
1 part masonry cement
1 part regular cement
5 parts sand
Stucco premix is available
at your local lumber yard or
building supply store�
Follow stucco manufacturer’s
instructions for correct mixing
information�
MINIMUM STUCCO
APPLICATION IS 25 mm
(1")