Specifications

An ongoing program of product improvement may require us to change
specifications without notice. WS-MS-(4, 5, 6, 7)-W-IR,
Revised May 2015. Doc no: M0036.04
11
Mountain Series
Installation and Operation Manual
info@woodstone-corp.com or visit woodstone-corp.com
wood stone corporation
1801 w. bakerview rd.
bellingham, wa 98226 usa
tf. 800.988.8103
t. 360.650.1111
f. 360.650.1166
GAS SPECIFICATIONS
Model SV-1
WS-MS-4-W-IR-NG 3�5"
WS-MS-5-W-IR-NG 3�5"
WS-MS-6-W-IR-NG 3�5"
WS-MS-7-W-IR-NG 3�5"
Model SV-1
WS-MS-4-W-IR-LP 9"
WS-MS-5-W-IR-LP 9"
WS-MS-6-W-IR-LP 9"
WS-MS-7-W-IR-LP
9�2"
Model SV-1
WS-MS-4-W-IR-HLP 9"
WS-MS-5-W-IR-HLP 9"
WS-MS-6-W-IR-HLP 9"
WS-MS-7-W-IR-HLP
9�2"
The Wood Stone Gas ovens are equipped with a 3/4" NPT gas connection located at the rear left of the oven� Have a
licensed gas installer provide the hook-up and test all fittings and pipe connections for leaks� Use approved gas leak
detectors (soap solutions or equivalent) over and around the fittings and pipe connections� DO NOT USE FLAME TO
TEST FOR LEAKS!
SV-1 is the gas control valve that operates the Underfloor Infrared (IR) burner The manifold pressure test port is 1/8: NPT
pugged tap located on the IR burner manifold�
The burner manifold pressure has been adjusted and tested at the factory A variety of factors can influence this pressure,
so be sure to test the burner manifold pressure and adjust the valve as necessary to achieve the specified pressure�
NOTE: Maximum inlet gas pressure: 1/2 psi (14 inches W.C.)
This oven requires no modifications or adjustments for use at high altitudes.
Factory specified individual burner manifold pressures (W.C.) for W-IR models equipped to burn wood and
Natural Gas (NG)
Factory specified individual burner manifold pressures (W.C.) for models equipped to burn wood and
Propane (LP & HLP)