User Manual
Based on product information at time of printing.
Valve Grinder
Rev. 0.0 / 02-06
P.O. Box 368 - 908 West Main 1-800-548-7341 Fax: 1-406-628-8354
Laurel, MT 59044 1-406-628-8231 www.powrgrip.com
U.S.A. Sold through authorized dealers
Products are manufactured under
an ISO 9001 quality management system
INSTRUCTIONS
V1275
Weight: 4 oz [110 g]
Intended Use: Pick up and position clean, relatively smooth, nonporous materials, at temperatures from 0° to 120° F [-18°
to 49° C]. See Vacuum Pads for capacities.
Cautions: Moisture or contaminants can reduce the slip resistance of vacuum pads. Test for staining or deformation of
surfaces with light colors or soft coatings.
Operation: To attach, depress the pump plunger while pressing the vacuum pad onto the valve. Then release the plunger.
Note: When the pad is attached correctly, the plunger should remain partially hidden within the handle; if not, make sure the
pad face and valve face are clean.
To release, set down the material and depress the plunger until the pad comes free.
Note: For quick pick-and-place operations, use a partial pump stroke to attach and a full stroke to release the material.
Vacuum Pads: Interchangeable pads are available to fit most standard valves.
Model No. Pad Dia. Max. Capacity
VG0750 3/4" [20 mm] 16 oz [455 g]
VG1000 1" [26 mm] 29 oz [824 g]
VG1250 1-1/4" [32 mm] 46 oz [1307 g]
Maintenance: Keep clean. Store in original pouch when not in use. Replace vacuum pads when worn or damaged.
The ULTIMATE vacuum stick for lapping 4-cycle valves.
Pump provides long-lasting hold. Plunger serves as a
leakage indicator, to help prevent unexpected release.