Owner's manual

Rev 1.0/6-13 7 CB1: #35168
MAINTENANCE
INSPECTIONS AND TESTING
When performing inspections and tests of the P2 Channel Lifter as directed in the MAINTENANCE
section of the lifter's instruction manual, be sure to include the Counter-Balancer whenever
applicable. Consult the following topics for additional directions.
Every-Lift Inspection:
• Examine the lift shackles and shackle pins for signs of wear or damage.
• Examine the lift slings for fraying or other signs of wear or damage.
• Be sure all fasteners are secure before use.
If any deficiency is detected during the inspection, correct it before using the Counter-Balancer
and perform the Frequent Inspection to follow.
Frequent Inspection:
• Examine all fasteners for signs of wear or damage.
• Be sure all fasteners are secure before use.
• Examine the Counter-Balancer’s structure for visual damage.
If any deficiency is detected during the inspection, correct it before using the Counter-Balancer
and perform the Periodic Inspection to follow.
Periodic Inspection:
• Examine the entire Counter-Balancer for external evidence of looseness, excessive wear,
deformation, cracks, excessive corrosion, dents to structural or functional components, cuts,
or any deficiency which might constitute a hazard.
• Keep a written record of all Periodic Inspections.
If any deficiency is detected during the inspection, return the Counter-Balancer to Wood’s Powr-
Grip or an authorized dealer for repair (see LIMITED WARRANTY).
Infrequent Use
If the Counter-Balancer is used less than 1 day in a 2-week period, perform the Periodic
Inspection
each time before using the Counter-Balancer
.