Instructions

3. Before you install the appliance, check that there are not any electrical or other
cables in the installation area; this prevents these cables from being drilled
unintentionally.
4. Clean the environment thoroughly before installation. This prevents dust or
rubble from being sucked in during initial operation of the appliance.
5. During installation ensure that the extractor hood is in horizontal position in
order to avoid accumulations of fat in one corner of the appliance.
2.1 Minimum distances
Strictly observe the minimum distance between hood and hob.
It is also absolutely necessary to observe the individual minimum
distances to extractor hoods which are specified in the instruction manual
of your hob / oven / etc.
REQUIRED MINIMUM DISTANCE HOOD TO
Ceramic-glass rings / hotplates
min. 65 cm
Gas cooker
min. 75 cm
Coal / oil / stove wood firing
min. 85 cm
1. The minimum distances do not represent the required total height but a minimum
value generated by adding the height of the hob (floor ↔ hob) and the required
minimum distance of the hob to the extractor hood (hob ↔ extractor hood)
(floor ↔ hob)
+
(hob ↔ extractor hood)
=
MINIMUM INSTALLATION HEIGHT
2. Adapt the total installation height to the height of the user. Please note that the
extraction capacity of the appliance can decrease if installed at a large distance to
the hob.
WARNING! Never install the appliance below the required
minimum distance. If you ignore the required minimum distance, the
accumulated fat in the filters can catch fire due to the heat emission of the
hob. RISK OF FIRE!
CAUTION! Any potential user has to be careful not to hit their head on
the corners and edges of the appliance. RISK OF BRUISES! RISK OF
INJURIES IN THE OCULAR AREA!