User manual

OSD
39 Version 1.5
Miscellaneous Settings
SCB-12
MISCELLANEOUS SETTINGS
IR Code
A
Erase Memory
MANUALLY
Image Turn Rotation
CYCLE
Digital Zoom
2X
Dig. Zoom Warning
STOP
Return
IR remote code: Helpful when there are IR interferences in the
same room as the SCB-12.
Factory setting is A
Possible settings:
A: IR code A
B: IR code B
C: IR code C
D: IR code D.
The IR remote control has to be set to the same IR code as the unit
to function correctly (see page 56).
For activating the new code select the line "Activate new IR-code
here".
Changes the behavior of erasing image memories.
Factory setting is MANUALLY
Possible settings:
MANUALLY: image memories can be erased only by keeping
pressed the ALL key for 4 seconds and pressing MEMORY 3
key
STAND-BY: image memories will be erased when switching the
unit on.
Images will be stored in a permanent memory without battery.
Changes the behavior of turning images by pressing the IMAGE
TURN key.
Factory setting is CYCLE
CYCLE: every time the IMAGE TURN key is pressed, the image
will be turned clockwise by 90° (0°, -90°, 180°, +90° and 0°)
-90: the image will be turned by -90°, when pressing the IMAGE
TURN key again; the image will be displayed in standard format.
180: the image will be turned by 180°, when pressing the IMAGE
TURN key again; the image will be displayed in standard format.
+90: the image will be turned by +90°, when pressing the IM-
AGE TURN key again; the image will be displayed in standard
format.
IR Code
Erase Memory
Image Turn Rotation