User manual

Connections
Version 1.5 24
7 Connections
7.1 DVI-I
The DVI-I port (#10) provides digital and analog signals with ad-
justable resolution and refresh rate.
For using HDMI, a DVI-HDMI cable or adapter will be required.
When using digital display devices with LCD-, DLP- or Plasma
technology, use the DVI port for getting the best result of image
reproduction. Because the signal will be not converted from digital
to analog to prevent signal loss.
7.2 RGB
The RGB port (#8) of the SCB-12 provides an analog RGBHV
signal with adjustable resolution and refresh rate
Use the RGB port for long cable runs and when using analog dis-
play devices.
7.3 Power Plug
When a locked power connector and/or other power supply are
necessary, the supplied power connector can be used.
The power supply is optional if Power over Ethernet (PoE) is used
(see page 27).
The power source equipment shall comply with all applicable local
and national codes related to safety.
7.4 RS-232
The serial port (#4) can be used to control the SCB-12 through an
external device, such as a room control system
Pins:
2: RX
3: TX
5: GND
Baud rate:
9200, 19200, 38400, 57600 or 115200
(selectable)
databits:
8
stopbit:
1
The baud rate can be changed in the on-screen extra menu (see
page 29ff).
The complete command protocol can be found on our internet
website under: www.wolfvision.com/support
DVI-I
socket on the unit
(front view)
D-Sub HD 15pin
socket on the unit
(front view)
DC-plug
pin diameter 2,1mm
(front view)
D-Sub 9pin
connector on the unit
(front view)