Design Guide
wolfappliance.com 
|
 69
Planning Information
GAS SUPPLY
A gas supply line of 
3
/4" (19) rigid pipe must be provided 
to the gas module. If local codes permit, a certied, 3'
 (.9 m) 
long, 
1
/2" (13) or 
3
/4" (19) ID exible metal appliance con-
nector is recommended to connect the units 
1
/2" NPT 
female inlet to the gas supply line.
When multiple gas cooktops or modules are installed side 
by side, they can receive their gas supply from a common 
line. However, each unit must have its own regulator 
installed between the mainline and the cooktop or module.
Wolf natural gas modules will function up to 10,250'
 (3124 m) 
in altitude without adjustment and LP gas modules will 
function up to 8,600'
 (2621 m). If the installation exceeds 
these elevations, contact an authorized Wolf dealer for a 
high altitude conversion kit.
WOLF INTEGRATED MODULES
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
OVENS / WARMING DRAWERS COOKTOPS / COFFEE SYSTEMS RANGES / RANGETOPS OUTDOOR GRILLS VENTILATION