Warming Drawer UCG
6 
|
 Wolf Customer Care 800.222.7820
Control Panel
The electronic control panel features touch controls and a 
visual display. Refer to the illustration below. The control 
panel is hidden when the warming drawer is closed. Open 
the drawer to access the control panel.
Temperature
The warming drawer features four preset temperature set-
tings; PROOF, LOW, MED and HIGH. During preheat, the 
temperature display will alternate between the set point and 
the actual temperature. ‘Lo’ will appear until the temperature 
reaches 85°F
 (30°C). An audible chime indicates preheat is 
complete. Refer to the chart below.
IMPORTANT NOTE: When warming towels, temperature can 
not exceed 120°F
 (50°C).
Setting temperature:
1    Touch POWER ON/OFF.
2    Touch one of the PRESETS to select the preset tempera-
ture or touch TEMP UP or DOWN arrows to select the 
desired temperature.
TEMPERATURE
SETTING PRESET RANGE
PROOF 85°F (30°C) 80–110°F (25–40°C)
LOW 120°F (50°C) 80–200°F (25–95°C)
MED 160°F (70°C) 80–200°F (25–95°C)
HIGH 200°F (95°C) 80–200°F (25–95°C)
Timer
The warming drawer has a built-in timer that will auto-
matically turn off after four hours of use. The timer can be 
adjusted from one minute to 24 hours.
Setting timer:
1    Select desired temperature.
2    Touch TIMER UP or DOWN arrows to select the desired 
time. ‘TIMER’ and the shut off time will appear in the 
display.
Custom Preset Setting
Customize a preset temperature setting using desired tem-
perature and timing duration (one minute to 24 hours) with 
automatic shut off.
Setting custom preset temperature and automatic shut off:
1    Touch POWER ON/OFF.
2    Touch and hold the desired preset for 5 seconds until 
‘TIMER’ and ‘4:00’ appear in the display.
3    Touch TEMP UP or DOWN arrows to select the desired 
temperature.
4    Touch TIMER UP or DOWN arrows to select the desired 
automatic shut off timing duration.
5    Touch and hold the desired preset again for 5 seconds 
to save the settings.
Control panel
WARMING DRAWER OPERATION