Design Guide
wolfappliance.com | 21
E Series Ovens
30" OVEN
Installation must comply with all applicable electrical codes. 
Locate the electrical supply flush with the back wall and 
within the shaded area shown in the illustrations on the 
following pages. For ease of installation, the electrical 
supply for the oven can be placed in an adjacent cabinet 
within reach of the conduit.
Performance may be compromised if the electrical supply 
is less than 240 volts.
The oven is supplied with a conduit consisting of two 
insulated hot lead conductors and a bare ground con-
ductor. The wiring diagram covering the control circuit is 
provided with the oven.
ELECTRICAL REQUIREMENTS—SINGLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp dedicated circuit
Conduit 4' (1.2 m)
Total Amps 22
Max Connected Load 5.4 kW
ELECTRICAL REQUIREMENTS —DOUBLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 50 amp dedicated circuit
Conduit 5' (1.5 m)
Total Amps 45
Max Connected Load 10.8 kW
Electrical Requirements
24" OVEN
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations 
on the following pages. A separate circuit servicing only 
this appliance is required. A ground fault circuit interrupter 
(GFCI) is not recommended and may cause interruption 
of operation. Refer to the illustration below for minimum 
power cord plug clearance.
Performance may be compromised if the electrical supply 
is less than 240 volts.
ELECTRICAL REQUIREMENTS—24" OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 20 amp dedicated circuit
Receptacle NEMA 6-20R grounding-type
Power Cord 6' (1.8 m)
1" (25)
MINIMUM
CORD
CLEARANCE
Power cord clearance