VHood IG

wolfappliance.com | 9
Wiring Connections
IN-LINE/REMOTE BLOWER WIRING
1 Remove the top cover of the electrical box by extract-
ing the two screws. Refer to the illustration.
2 Remove one of the round knockouts using a flat blade
screwdriver.
3 The terminal block is wired for an internal blower.
For in-line and remote blowers, the existing blue and
brown wires must be removed and placed in the two
left positions to accommodate the in-line or remote
blower wire. Refer to the illustration.
4 Insert Romex
®
wire from the in-line or remote blower
through the knockout and secure using an approved
cord stain relief.
5 Connect white to blue, black to brown and green to the
ground screw. Refer to the illustration.
6 Verify all wires are secure and not pinched between the
cover, and install the cover.
MOVE
WIRES HERE
WHITE
BLACK
GREEN
GROUND
BLUE
BROWN
TO IN-LINE/REMOTE
BLOWER
BLUE
BROWN
Wiring location
In-line/remote blower wiring
Installation