Contents Important Note Integrated Refrigeration . . . . . . . . . . . . . . . . . . . . . . . 3 To ensure the safe and efficient installation of Sub-Zero equipment, please take note of the following types of highlighted information throughout this guide: Model Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Integrated Installation . . . . . . . . . . . . . . . . . . . . . . . . 11 Service Information . .
Integrated Refrigeration 3 subzero.com Sub-Zero Integrated Refrigeration Before You Start The importance of the installation of the Sub-Zero integrated unit cannot be overemphasized. Installation should be done by a qualified installer. Make sure that the finished rough opening where the integrated unit is to be installed is properly prepared. Refer to the specifications for your specific model on the following pages.
Model Specifications 4 Overall Dimensions 27" (686) MODELS 27" (686) 24" (610) 14" (356) 13/16" (21) 78 9/16" (1995) 80" (2032) TO TOP OF OPENNG 3/8" (10) 1/2" (13) 27" (686) 3/8" (10) 13 1/4" 1/2" (13) (337) 24" (610) 13 1/4" (337) 34 1/2" (876) 10 1/4" (260) 34 1/2" 10 1/4" (260) (876) 20 3/8" (518) 20 3/8" (518) 9 3/4" 9 3/4" (248) (248) 4" HEIGHT DIMENSIONS ± 1/2" (13) HEIGHT DIMENSIONS ± 1/2" (13) (102) 24" 24" (610) (610) 4 5/8" (117) 191/2" 251/2" 191/2" (495)
Model Specifications 5 subzero.com Overall Dimensions 36" (914) MODELS 36" (914) 24" (610) 14" (356) 1 5/16" (33) 77 13/16" (1976) 80" (2032) TO TOP OF OPENNG 3/8" (10) 1/2" (13) 13 1/4" (337) 10 1/4" 34 1/2" (876) (260) 20 3/8" (518) 9 3/4" (248) 4" HEIGHT DIMENSIONS ± 1/2" (13) (102) Interior Capacity and Weight Interior Capacity R cu ft (L) F cu ft (L) 27" (686) TALL UNITS 24" (610) 700TR 700TF(I) 700TC(I) 7" (178) 15.5 (439) 10.2 (289) 15.3 (433) 5.
Site Preparation 6 Opening Dimensions INTEGRATED MODELS TOP VIEW 25" (635) OPENING DEPTH 25" (635) OPENING DEPTH B A OPENING HEIGHT OPENING WIDTH SIDE VIEW Opening Width FRONT VIEW A 700TR, 700TF(I) and 700TC(I) 27" (686) 700BR, 700BF(I) and 700BC(I) 27" (686) 736TR, 736TFI and 736TCI 36" (914) IMPORTANT NOTE: The depth of each integrated model is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit.
Site Preparation 7 subzero.com Electrical Requirements The electrical supply should be located within the shaded area shown in the illustrations. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. IMPORTANT NOTE: It is critical that the electrical outlet be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket.
Site Preparation 8 Plumbing Requirements For integrated models with an automatic ice maker, the water supply line should be located through the floor or back wall, within the shaded area shown in the illustrations. Routing the line in these locations will avoid any interference with the anti-tip bracket. The water supply line should be connected to the house supply with an easily accessible shut-off valve between the supply and the unit. Do not use self-piercing valves.
Site Preparation 9 subzero.com Anti-Tip Bracket Installation WOOD FLOOR APPLICATIONS To prevent the unit from tipping forward and provide a stable installation, the unit must be secured in place with the anti-tip brackets shipped with the unit. An anti-tip bracket and hardware is provided with the integrated unit. Placement of the anti-tip bracket is critical to a stable installation. The anti-tip bracket must be installed on a solid base.
Site Preparation 10 Anti-Tip Bracket Installation Unpacking and Moving INSTALL CONCRETE WEDGE ANCHORS: Uncrate the unit and inspect for any damages. Remove the wood base and discard the shipping bolts that hold the wood base to the bottom of the unit. Remove and discard all packing materials. 1) Drill a 3/8" (10) diameter hole any depth exceeding the minimum embedment. Clean the hole or continue drilling additional depth to accommodate drill fines. Use a carbide drill bit manufactured within ANSI B94.
Integrated Installation 11 subzero.com Position the Unit Before moving the integrated unit into position, protect any finished flooring, secure the door closed and remove the drawers. IMPORTANT NOTE: For drawer units, the top drawer has a control cable that needs to be disconnected before removing this drawer. Refer to the illustration below for placement and how to disconnect this fitting. The drawers should be placed aside until you are ready for installation of the panels.
Integrated Installation 12 Level the Unit Molding Installation Level the integrated unit by turning the front leveling legs clockwise to raise the unit, or counterclockwise to lower it. To assist you in adjusting the front leveling legs up or down, use a standard screwdriver blade and place it in the front leveling leg as shown in the illustration below. The decorative white molding strips for the side and top of the unit can be snapped into place.
Integrated Installation 13 subzero.com Water Line Connection QUICK CONNECT WATER VALVE For units with an ice maker, the quick connect water valve and PEX tubing are located on the bottom right side of the unit. To connect the ice maker water line, attach the union fitting to the copper house water supply line. Pull the coiled gray PEX tubing with red cap and captured nut toward the house water supply line. Remove and discard the red cap. Then attach the tubing to the union with the nut.
Integrated Installation 14 Kickplate/Grille Installation Once the integrated unit is secured, the kickplate/grille can be installed. The mounting bracket may be adjusted slightly forward or back so the kickplate/grille will fit flush with the surrounding area. Refer to the illustration below. The kickplate/grille must be removable for servicing. The floor cannot interfere with removal. IMPORTANT NOTE: The unit must be allowed to have ventilation through the fins of the kickplate/grille.
Integrated Installation 15 subzero.com Panel Installation The integrated design uses custom wood or other decorative panels and handles provided by the customer. Stainless steel panels are available as sales accessories through your Sub-Zero dealer. To obtain local dealer information, visit the showroom locator section of our website, subzero.com. Check panel dimensions before proceeding. Additional panel information can be found in the Sub-Zero design guide. Visit our website, subzero.com.
Integrated Installation 16 Panel Installation DOOR PANEL INSTALLATION PANEL BRACKET POSITIONING Before attaching the door panel to the door, place two screws in the center of each mounting position, just enough that the slotted holes on the hinge side door panel bracket will slide under the heads. These positioning screws will support the door panel during installation and adjustment. Refer to the illustration below. The illustration below shows mounting hardware location for door and drawer panels.
Integrated Installation 17 subzero.com Panel Installation DRAWER PANEL INSTALLATION Remove the mounting hardware provided and set aside. As with the door panel, you should work on the back side of each drawer panel to protect the front surface. Position the top edge of the template (provided) flush with the top edge of each drawer. For the top drawer, there is only one location for the lower mounting bracket.
Integrated Installation 18 Dual Installations Installation Checklist When two integrated units are installed closer than 2" (51) to one another, it is necessary to use the Sub-Zero dual installation heater kit (7007529 or 7007530). The heater plate from this kit must be attached to the left side exterior of the right-hand unit before the units are slid into position.
Service Information 19 subzero.com Service Information If service is necessary, maintain the quality built into your Sub-Zero unit by calling a Sub-Zero authorized service center. To obtain the name and number of a Sub-Zero authorized service center, check the contact & support section of our website, subzero.com or call Sub-Zero customer service at 800-222-7820. If you are storing or disposing of your old refrigerator or freezer, please do it safely. Remove the doors or tightly secure the doors closed.