Wolf Design Guide
146
|
Wolf Customer Care 800.222.7820
RECIRCULATING APPLICATION
The ceiling-mounted hood with an internal blower only, can
be installed in a recirculating application. The air discharge
must be a minimum of 40"
(1016) from every side of the
hood. Refer to the illustration below. The ductwork and vent
cover are not provided. A recirculation kit, available through
an authorized Wolf dealer, is required.
Planning Information
Installation of the ceiling-mounted hood should be 36" (914)
to 84"
(2134) from the bottom of the hood to the countertop.
The hood can be operated using the remote control or the
control panel located on the right side of the hood.
The hood is shipped without a blower assembly. Internal,
in-line, and remote blowers are avail able through an autho-
rized Wolf dealer. For local dealer information, visit the nd a
showroom section of our website, wolfappliance.com. Refer
to Ventilation Suggestions on pages 166–169.
Ceiling-mounted hoods include a 6"
(152) round discharge
for internal blowers and a 10"
(254) round discharge for in-
line and remote blowers. For an internal blower, the blower
box can be rotated to discharge right, left, front, or rear. For
an in-line or remote blower, the discharge is vertical only.
Consult a qualied HVAC professional for specic installa-
tion and ducting applications.
40"
(
1016
)
MIN
Recirculating application
COOKTOP VENTILATION