ELECTRICAL REQUIREMENTS—SINGLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp dedicated circuit
Conduit 4' (1.2 m)
Total Amps 22
Max Connected Load 5.4 kW
ELECTRICAL REQUIREMENTS —DOUBLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 50 amp dedicated circuit
Conduit 5' (1.5 m)
Total Amps 45
Max Connected Load 10.8 kW
Specifications
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the oven can be placed in an adjacent cabinet
within reach of the conduit.
Performance may be compromised if the electrical supply
is less than 240 volts.
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground con-
ductor. The wiring diagram covering the control circuit is
provided with the oven.