Installation Guide

wolfappliance.com
|
9
INSTALLATION
Low-Prole Wall Hood
INSTALLATION
WARNING
Wall framing must be able to support the weight of the
hood and internal blower, if applicable.
1 Refer to the illustration for typical wall framing. Additional
framing or blocking is required in the mounting bracket
location.
2 Position the mounting brackets on the wall as shown
in the illustration below. Secure the brackets to the wall
framing and blocking with the provided screws and
washers.
26
1
/4" (667)
MOUNTING BRACKET
CENTERS
7
1
/4" (189)
TO BOTTOM
OF HOOD
BLOCKING
C
L
Mounting bracket location
3 Install the transition. For an internal blower, the transi-
tion is included with the blower. For in-line and remote
blowers, a transition is required (not provided). Refer to
the illustration below.
4 Place the hood on the mounting brackets. Secure with
the provided screws through the mounting holes on the
back panel. Verify the screws engage the wall framing or
blocking. If additional support is required, drill supple-
mentary holes through the back panel and secure with
screws and washers.
5 Insert Romex
®
wire(s) into the electrical box knockout
and secure with a UL or C/UL approved connector (not
provided).
6 Connect the ducting to the transition and secure with
duct sealing tape.
TRANSITION
ELECTRICAL
BOX
(INSIDE HOOD)
Transition (internal blower)
Electrical box location