Installation Guide
12
|
Wolf Customer Care 800.222.7820
INSTALLATION
Electrical Connections
WARNING
Before making electrical connections, verify power is
turned off at the service panel.
IMPORTANT NOTE: Refer to installation instructions pro-
vided with the blower assembly.
INTERNAL BLOWER
1 Remove the hood’s electrical box cover.
2 Connect black to black and white to white with the
provided connectors, and connect the green/bare wire
to the ground screw.
3 Place all wiring connections inside the electrical box.
Verify all wires are secure and not pinched, and reinstall
the cover.
4 Insert the blower power cord into the receptacle inside
the hood. Refer to the illustration below. Turn the power
on and check operation.
IN-LINE/REMOTE BLOWER
1 Remove the hood’s electrical box cover.
2 Connect the home supply. Connect black to black and
white to white with the provided connectors, and con-
nect the green/bare wire to the ground screw.
3 Connect the blower supply to the power cord provided
with the blower. Connect black to black, white to white,
and the green/bare wire to the ground screw.
4 Place all wiring connections inside the electrical box.
Verify all wires are secure and not pinched, and reinstall
the cover.
5 Insert the blower power cord into the receptacle inside
the hood. Refer to the illustration below. Turn the power
on and check operation.
RECEPTACLE
ELECTRICAL
BOX
Blower receptacle
RECEPTACLE
ELECTRICAL
BOX
Blower receptacle