INSTALLATION
Electrical Connections
 WARNING
Before making electrical connections, verify the power 
is turned off at the service panel.
IMPORTANT NOTE: Refer to installation instructions pro-
vided with the blower assembly. 
INTERNAL BLOWER
1   Connect black to black and white to white with the 
provided connectors, and connect the green/bare wire 
to the ground screw.
2   Verify all wires are secure and not pinched, and reinstall 
the box.
3   Plug the blower power cord into the receptacle inside 
the hood. Refer to the illustration below.
4   Turn on the power to the hood and verify light and 
blower operation.
IN-LINE/REMOTE BLOWER
1   Remove the connector from the end of the orange wire.
2   Connect the home supply. Connect black to black and 
connect the green/bare wire to the ground screw.
3   Connect the blower supply. Connect black to orange, 
all three white wires, and connect the green/bare wire to 
the ground screw.
4   Verify all wires are secure and not pinched, and reinstall 
the box.
5   Turn on the power to the hood and verify light and 
blower operation.