Pro Wall Chimney Hoods IG
6 | Wolf Customer Care 800.222.7820
INSTALLATION
Installation
 WARNING
Wall framing must be able to support the weight of the 
hood and internal blower, if applicable.
1   Refer to the illustration below for typical wall framing. 
Additional framing or blocking is required in the 
mounting strip location.
C
L
BLOCKING
MOUNTING
STRIP
18"
(457) 
TO BOTTOM
OF HOOD
Wall framing (typical)
Hood Preparation
 Remove the lters prior to installation. To remove, press 
the lter upward and rotate the bottom. Remove the grease 
cups from the bottom edge of the hood. Refer to the illustra-
tion below.
SIDE VIEW
SPRING
FILTER
GREASE
CUP
Filters