Specifications

8
W O L F P R O WA L L V E N T I L AT I O N H O O D S
T R A N S I T I O N S P E C I F I C AT I O N S
The illustrations and chart provide dimensions
specific to Pro low-profile wall hood models
with different transition applications. These
dimensions are critical for proper installation.
Low-Profile Wall Hoods 10" (254) Round Accessory Transition
(in-line or remote blower)
Model (A) (B) (C) (D)
PW302210 30" (762) 9" (229) 14
3
/4" (375) 5
5
/8" (143)
PW362210 36" (914) 9" (229) 17
3
/4" (451) 5
5
/8" (143)
PW422210 42" (1067) 9" (229) 20
3
/4" (527) 5
5
/8" (143)
PW482210 48" (1219) 9" (229) 23
3
/4" (603) 5
5
/8" (143)
Low-Profile Wall Hoods Vertical Discharge
Model (A) (B) (C) (D)
PW302210 30" (762) 1
1
/2" (38) 14
3
/4" (375) 2
5
/8" (60)
PW362210 36" (914) 1
1
/2" (38) 17
3
/4" (451) 2
5
/8" (60)
PW422210* 42" (1067) –20
3
/4" (527) 2
5
/8" (60)
PW482210* 48" (1219) –23
3
/4" (603) 2
5
/8" (60)
Low-Profile Wall Hoods Horizontal Discharge
Model (A) (B) (C) (D)
PW302210 30" (762) 1
1
/2" (38) 14
3
/4" (375) 2" (51)
PW362210 36" (914) 1
1
/2" (38) 17
3
/4" (451) 2" (51)
PW422210* 42" (1067) –20
3
/4" (527) 2" (51)
PW482210* 48" (1219) –23
3
/4" (603) 2" (51)
*500 CFM blower not available for these models.
Low-Profile Wall Hoods
10" (254) Round Accessory Transition
D
C
TO CENTER
OF TRANSITION
T
O CENTER
OF TRANSITION
B
HEIGHT OF
TRANSITION
A
WIDTH
OF HOOD
Low-Profile Wall Hoods Vertical Discharge
C
TO CENTER
OF TRANSITION
A
WIDTH
OF HOOD
D
TO CENTER
OF TRANSITION
B
HEIGHT OF
TRANSITION
Low-Profile Wall Hoods Horizontal Discharge
A
WIDTH
OF HOOD
B
HEIGHT OF
TRANSITION
C
TO CENTER
OF TRANSITION
D
TO CENTER
OF
TRANSITION
IMPORTANT NOTE:
The transition included
with the 500 CFM internal blower accommo-
dates 3
1
/4" (83) x 10" (254) ductwork. An
optional 3
1
/4" (83) x 10" (254) to 8" (203) round
transition is available as a sales accessory.
Contact your Wolf dealer for details.
Low-Profile Wall Hoods
No Transition
RECTANGULAR
CUT-OUT
3
1
/4
"
(83)
14"
(356)