installation guide

wolfappliance.com | 5
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations and
chart below. A separate circuit, servicing only this appliance
is required.
A ground fault circuit interrupter (GFCI) is required to reduce
the risk of electrical shock.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
ELECTRICAL KNOCKOUT LOCATION A
36" (914) Hood 16" (406)
48" (1219) Hood 22" (559)
60" (1524) Hood 28" (711)
SPECIFICATIONS
17"
(432)
A
2
5
/8"
(67)
Electrical knockout location
Rating plate location
RATING PLATE
Discharge
Outdoor Wall Hoods have a vertical discharge. Refer to the
illustration below.
2" (51)
Vertical discharge
36" (914) TO 42" (1067) BOTTOM EDGE TO COUNTERTOP
Hood location