Specifications

82
|
Wolf Customer Care 800.222.7820
WOLF GAS RANGES
RANGES / RANGETOPSVENTILATION COOKTOPS / COFFEE SYSTEMS OVENS / WARMING DRAWERSOUTDOOR GRILLS
GAS SUPPLY
A gas supply line of
3
/4" (19) rigid pipe must be provided to
the range. If local codes permit, a certied, 3'
(.9 m) long,
1
/2" (13) or
3
/4" (19) ID exible metal appliance connector is
recommended to connect the units
1
/2" NPT female inlet to
the gas supply line.
Wolf natural gas ranges will function up to 8,600'
(2621 m) in
altitude without adjustment. If the installation exceeds this
elevation, contact an authorized Wolf dealer for a high alti-
tude conversion kit. LP models do not require conversion.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
Planning Information
When installing against a combustible surface, a minimum
20"
(508) riser is required. Follow all minimum clearances to
combustible surfaces shown in the illustration on the fol-
lowing page.
ELECTRICAL
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 110/120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6' (1.8 m)