P R O W A L L V E N T I L AT I O N H O O D S I NSTALLATION I NSTRUCTIONS
C O N TA C T I N F O R M AT I O N Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions.
W O L F P R O WA L L V E N T I L AT I O N H O O D S I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Installer: Please read the entire Installation Instructions prior to installation. Save these instructions for the local inspector’s reference, then leave them with the homeowner.
W O L F P R O WA L L V E N T I L AT I O N H O O D S I N S TA L L AT I O N C O N S I D E R A T I O N S ACCESSORIES Optional accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com. Wolf Pro wall ventilation hoods are recommended for use with all Wolf cooking appliances. IMPORTANT NOTE: Wolf recommends that the Pro wall ventilation hood be installed 30" (762) to 36" (914) above the countertop.
I N S TA L L AT I O N I N S T R U C T I O N S OV E R A L L D I M E N S I O N S L O W- P R O F I L E WA L L H O O D S 12" Overall Widths (305) 30" (762), 36" (914), 42" (1067) and 48" (1219) Overall Height 10" (254) Overall Depth (excluding rail) 22" (559) Shipping Weight (shell only) Dimensions may vary to ± 1/8" 39–55 lbs (18–25 kg) (3).
W O L F P R O WA L L V E N T I L AT I O N H O O D S I N S TA L L AT I O N S P E C I F I C A T I O N S Low-Profile and 24" (610) Deep Wall Hoods 6" LOCATION OF ELECTRICAL (152) E 5" (127) 10" (254) 18" (457) HEIGHT OF HOOD WIDTH OF HOOD 30" TO 36" (762–914) TO COUNTERTOP 30" TO 36" (762–914) TO COUNTERTOP 22" (559) 24" (610) DEPTH OF HOOD NOTE: Low-profile and 24" (610) deep wall hoods have a vertical or horizontal discharge; discharge direction varies with blower model.
I N S TA L L AT I O N I N S T R U C T I O N S I N S TA L L AT I O N S P E C I F I C A T I O N S The following chart provides dimensions specific to each wall hood model. These dimensions are critical for proper installation. Also refer to the illustration below.
W O L F P R O WA L L V E N T I L AT I O N H O O D S L OW- P R O F I L E A N D 2 4 " ( 6 1 0 ) H O O D S S T E P 1 : I N S TA L L D U C T W O R K DUCTWORK INSTALLATION THROUGH ROOF To reduce the risk of fire, use only metal ductwork.
I N S TA L L AT I O N I N S T R U C T I O N S L OW- P R O F I L E A N D 2 4 " ( 6 1 0 ) H O O D S Always install a roof or wall cap if you are not installing a remote blower. Connect 8" (203) round metal ductwork for low-profile hoods or 10" (254) round metal ductwork for 24" (610) deep hoods to the cap and work back towards the hood. Use duct sealing tape on joints between ductwork sections.
W O L F P R O WA L L V E N T I L AT I O N H O O D S L OW- P R O F I L E A N D 2 4 " ( 6 1 0 ) H O O D S Refer to the illustrations below for the location of mounting holes for the low-profile and 24" (610) deep wall hoods. S T E P 2 : WA L L P R E PA R AT I O N ACCESSORIES Framing must be tied together and to ceiling joists to provide enough structural strength to support the weight of the hood and internal blower, if applicable. Optional accessories are available through your Wolf dealer.
I N S TA L L AT I O N I N S T R U C T I O N S L OW- P R O F I L E A N D 2 4 " ( 6 1 0 ) H O O D S Separate the transition from the rough-in plate by removing the four shipping screws. Do not discard the screws; they will be needed to reinstall the transition to the rough-in plate. Determine the direction of discharge for your installation and rotate the back panel accordingly. The wall hood back panel has been designed to accommodate a vertical or horizontal discharge.
W O L F P R O WA L L V E N T I L AT I O N H O O D S L OW- P R O F I L E A N D 2 4 " ( 6 1 0 ) H O O D S S T E P 5 : I N S TA L L T H E H O O D C O M P L E T E T H E I N S TA L L AT I O N IMPORTANT NOTE: If a backsplash is to be used, it should be installed before the wall hood is mounted. To complete the installation for the low-profile and 24" (610) deep wall hoods, follow Step 6: Install Wiring and refer to information on pages 17–19 for internal, in-line and remote blowers.
I N S TA L L AT I O N I N S T R U C T I O N S 27" (686) DEEP WA L L H O O D S S T E P 1 : I N S TA L L D U C T W O R K DUCTWORK INSTALLATION THROUGH ROOF To reduce the risk of fire, use only metal ductwork. ROOF CAP OR REMOTE BLOWER 10" ROUND DUCT IMPORTANT NOTE: Wolf recommends that the Pro wall ventilation hood be installed 30" (762) to 36" (914) above the countertop.
W O L F P R O WA L L V E N T I L AT I O N H O O D S 27" (686) DEEP WA L L H O O D S The hood assembly is shipped with the rough-in plate/transition attached. The transition is shipped upside down in the top of the hood. It must be removed and reinstalled in the proper position. S T E P 2 : WA L L P R E PA R AT I O N ACCESSORIES Optional accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.
I N S TA L L AT I O N I N S T R U C T I O N S 27" (686) DEEP WA L L H O O D S If you are installing WBLOWER-90INT or WBLOWER-120INT, refer to the internal blower information on page 17 and follow installation instructions provided with the blower. If you are installing an in-line or remote blower, drill a 7/8" (22) hole through the wood framing for the conduit. Refer to the in-line and remote blower information on pages 18–19 and follow installation instructions provided with the blower.
W O L F P R O WA L L V E N T I L AT I O N H O O D S P R O WA L L V E N T I L A T I O N H O O D S S T E P 6 : I N S TA L L W I R I N G This ventilation hood must be properly grounded. This unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes. I M P O R TA N T N OT E You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
I N S TA L L AT I O N I N S T R U C T I O N S INTERNAL B L OW E R S IMPORTANT NOTE: Refer to the specific installation instructions provided with each internal blower for additional mounting and wiring instructions. IMPORTANT NOTE: Use wire connectors or wire nuts approved by UL or C/UL. IMPORTANT NOTE: Wolf recommends installing the internal blower to the rough-in plate assembly prior to installing the hood to the wall framing.
W O L F P R O WA L L V E N T I L AT I O N H O O D S I N - L I N E A N D R E M OT E B L O W E R S Be sure that there is enough space for any transitions that may be needed between the blower and the connecting ductwork. For best performance, locate transitions nearest the blower. B L O W E R I N S TA L L AT I O N IMPORTANT NOTE: Refer to the specific installation instructions provided with each blower for additional mounting instructions.
I N S TA L L AT I O N I N S T R U C T I O N S I N - L I N E A N D R E M OT E B L O W E R S Plug the cord assembly into the receptacle located near the center of the hood shell. Use the clips on the interior of the hood to keep excess power cord away from moving parts. BLOWER WIRING IMPORTANT NOTE: Refer to the specific installation instructions provided with each blower for additional wiring instructions.
W O L F P R O WA L L V E N T I L AT I O N H O O D S B L OW E R A S S E M B L I E S Wolf Pro wall ventilation hoods are shipped without the blower assembly. Wolf internal, in-line and remote blower assemblies are available as sales accessories through your Wolf dealer. IMPORTANT NOTE: Blower options vary with the cooking surface. Use only a Wolf blower with the Pro wall ventilation hood. Refer to the Wolf Design Guide for Pro ventilation recommendations. You can also visit our website at wolfappliance.com.
I N S TA L L AT I O N I N S T R U C T I O N S D U C T C OV E R I N S T A L L A T I O N I N S T A L L F I LT E R S / G R E A S E C U P S Remove all packaging material from the filters and grease cups. Installing a duct cover assembly will impact all aspects of the hood installation including hood location, ducting, electrical placement and the mounting surface. Slide the grease cups along the bottom edge of the hood so that the lip of the grease cup overhangs slightly.
W O L F P R O WA L L V E N T I L AT I O N H O O D S C O N TA C T I N F O R M AT I O N Wolf Customer Service: 800-332-9513 Website: wolfappliance.com N A M E P L AT E I N S T A L L A T I O N TROUBLES H O OT I N G The Wolf logo nameplate does not come installed on the hood since there are various locations that the nameplate can be attached. Also, some customers prefer not to have a nameplate on their hood.
LEFT OUTER EDGE OF HOOD 23 BOTTOM EDGE OF HOOD CUT-OUT FOR LOGO PLACEMENT FOLD LINE FOR LOGO PLACEMENT
W O L F A P P L I A N C E C O M PA N Y, I N C. 809340 7 / 2006 P. O. B OX 4 4 8 4 8 MADISON, WI 53744 800-332-9513 W O L FA P P L I A N C E .