INSTALLATION GUIDE Pro Island Ventilation Hoods READ AND SAVE THESE INSTRUCTIONS
Contents Important Note Wolf Pro Island Ventilation Hoods. . . . . . . . . . . . . . . . . 3 To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation Considerations . . . . . . . . . . . . . . . . . . . . . . 5 Pro Island Hood Specifications . . . . . . . . . . . . . . . . . . 6 Pro Island Hood Installation . . . . . . . . . .
Wolf Pro Island Ventilation Hoods 3 wolfappliance.com/specs Pro Island Hood Installation IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference.
Safety Instructions 4 IMPORTANT INSTRUCTIONS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING: • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. • Two installers are recommended due to the size and weight of the pro ventilation hood. • Install the pro ventilation hood only with a blower manufactured by Wolf.
Installation Considerations 5 wolfappliance.com/specs Installation Considerations Wolf pro ventilation hoods are recommended for use with all Wolf cooking appliances. Island hoods should be larger than the cooking surface by 3" (76) on each side. The ventilation hood should be installed 30" (762) to 36" (914) above the countertop. • Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Wolf warranty.
Pro Island Hood Specifications 6 Overall Dimensions PRO ISLAND HOODS WIDTH MINUS 18" (457) 13" (330) 18" (457) OVERALL HEIGHT 4" (102) 36" (914), 42" (1067), 54" (1372) AND 66" (1676) WIDTHS 34" (864) OVERALL DEPTH Installation Specifications PRO ISLAND HOODS LOCATION OF ELECTRICAL THROUGH TOP OF HOOD 18" (457) HEIGHT OF HOOD 34" (864) DEPTH OF HOOD WIDTH OF HOOD 30" (762) TO 36" (914) TO COUNTERTOP
Pro Island Hood Specifications 7 wolfappliance.com/specs Installation Specifications Electrical Requirements The illustration below provides dimensions critical for proper installation of the pro island hood. Dimensions A and B in the illustration will vary with the width of the hood. Refer to the chart below. Wolf pro ventilation hoods require a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker.
Pro Island Hood Installation 8 Install Ductwork PRO ISLAND HOODS To reduce the risk of fire, use only metal ductwork. IMPORTANT NOTE: Pro ventilation hoods must exhaust to the outdoors. Wolf recommends that the pro island hood be installed 30" (762) to 36" (914) above the countertop. Consult a qualified HVAC engineer for specific ducting applications. DUCTWORK INSTALLATION THROUGH ROOF A 10" (254) round duct is recommended for pro ventilation hoods.
Pro Island Hood Installation 9 wolfappliance.com/specs Ceiling Framing IMPORTANT NOTE: A minimum 10" (254) opening in the ceiling is required to accommodate the ductwork necessary for proper ventilation. 1) Layout dimensions of the top plate of the hood (or top of duct cover) on the ceiling. The top plate dimensions will vary with the width of the island hood. Refer to the illustration and chart on page 7. 2) Construct the ceiling framing using minimum 2" x 4" lumber.
Pro Island Hood Installation 10 Duct Cover IMPORTANT NOTE: If an optional duct cover is to be used with the pro island hood, it must be attached before installing the hood. Installing a duct cover will impact all aspects of the hood installation, including hood location, ducting, electrical placement and the mounting surface. DUCT COVER INSTALLATION 1) Use the four 1/4" x 3" (76) lag screws and washers (provided with hood) to attach the duct cover to ceiling framing.
Pro Island Hood Installation 11 wolfappliance.com/specs Hood Preparation 1) Remove the filters of the pro island hood by pushing each filter up at the angle it is placed in, and rotate the bottom of the filter down. Refer to the illustration below. Gloves should be worn when handling filters. 2) Slide the grease cups out from the bottom edges of the front and back of the hood.
Pro Island Hood Installation 12 Hood Installation INSTALLATION WITHOUT DUCT COVER Due to the weight of the hood, be sure to have adequate assistance for installation. IMPORTANT NOTE: If an optional duct cover is to be used, it must be installed before installing the island hood. Refer to duct cover installation on page 10. The filters and internal frame must be removed from the hood prior to installation. Refer to hood preparation on the previous page.
Pro Island Hood Installation 13 wolfappliance.com/specs Blower Assemblies Internal Blower Pro ventilation hoods are shipped without the blower assembly. Internal, in-line and remote blowers are available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
Pro Island Hood Installation 14 Internal Blower IMPORTANT NOTE: Refer to specific installation instructions provided with each blower assembly for additional mounting and wiring instructions. THREADED STUD SLOT BLOWER INSTALLATION TAB 1) Discard the hex nuts provided with the blower. 2) Lift the blower assembly into position inside the hood. 3) Engage the two tabs on the blower into the two slots in the top plate of the island hood.
Pro Island Hood Installation 15 wolfappliance.com/specs In-Line and Remote Blowers WIRING FOR IN-LINE OR REMOTE BLOWER 1) Remove the hood electrical box cover. Run Romex® wire from a 120 V AC, 15 amp circuit to the hood installation location. Insert the Romex® wire into the electrical box by running it through the wire clamp previously installed. Tighten the wire clamp to secure the wire. Refer to the illustration and chart on the previous page for the location of wiring for your specific hood.
Pro Island Hood Installation 16 In-Line and Remote Blowers Allow enough space for transitions needed between the blower and connecting ductwork. For best performance, locate transitions nearest the blower. BLOWER INSTALLATION IMPORTANT NOTE: Refer to specific installation instructions provided with each blower assembly for additional mounting and wiring instructions. Locate the blower so that the length of the duct run and number of elbows and transitions are kept to a minimum.
Pro Island Hood Installation 17 wolfappliance.com/specs Complete the Installation INSTALL FILTERS LOGO NAMEPLATE Reinstall the internal frame on the island hood. Refer to hood preparation on page 11. The Wolf logo nameplate does not come installed on the island hood since there are various locations that the nameplate can be attached. Slide the grease cups along the bottom edge of the hood so that the lip of the grease cup overhangs slightly.
Service Information 18 Troubleshooting Service Information IMPORTANT NOTE: If the pro ventilation hood does not operate properly, follow these troubleshooting steps: If service is necessary, maintain the quality built into your ventilation hood by calling a Wolf authorized service center. • Verify that electrical power is being supplied to the ventilation hood. • Check electrical connections to ensure that the installation has been completed correctly.
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc.
WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 817001 REV-A 8/ 2010 WOLFAPPLIANCE.COM 800.332.