Specifications
61
P RO S ERIES V ENTILATION R ECOMMENDATIONS
BLOWER CROSS-REFERENCE
Wall Hoods – 24" (610 mm) Deep Blower Number Round Duct Discharge
W302418, W362418 or W422418 Internal 900 CFM WBLOWER-90INT (805086) 10" (254 mm) Vertical
W302418, W362418 or W422418 Remote 600 CFM CTBLOWER-60REM (801640) 10" (254 mm) Adjustable
W302418, W362418 or W422418 Remote 900 CFM CTBLOWER-90REM (801641) 10" (254 mm) Adjustable
W302418, W362418 or W422418 Remote 1200 CFM CTBLOWER-120REM (801642) 10" (254 mm) Adjustable
W302418, W362418 or W422418 Remote 1500 CFM CTBLOWER-150REM (804701) 10" (254 mm) Adjustable
W482418, W542418, W602418 or W662418 Internal 1200 CFM WBLOWER-120INT (804702) 10" (254 mm) Adjustable
W482418, W542418, W602418 or W662418 Remote 900 CFM CTBLOWER-90REM (801641) 10" (254 mm) Adjustable
W482418, W542418, W602418 or W662418 Remote 1200 CFM CTBLOWER-120REM (801642) 10" (254 mm) Adjustable
W482418, W542418, W602418 or W662418 Remote 1500 CFM CTBLOWER-150REM (804701) 10" (254 mm) Adjustable
NOTE: Transition with backdraft damper included.
Wall Hoods – 27" (686 mm) Deep Blower Number Round Duct Discharge
W302718, W362718 or W422718 Internal 900 CFM WBLOWER-90INT (805086) 10" (254 mm) Vertical
W302718, W362718 or W422718 Remote 600 CFM CTBLOWER-60REM (801640) 10" (254 mm) Vertical
W302718, W362718 or W422718 Remote 900 CFM CTBLOWER-90REM (801641) 10" (254 mm) Vertical
W302718, W362718 or W422718 Remote 1200 CFM CTBLOWER-120REM (801642) 10" (254 mm) Vertical
W302718, W362718 or W422718 Remote 1500 CFM CTBLOWER-150REM (804701) 10" (254 mm) Vertical
W482718, W542718, W602718 or W662718 Internal 1200 CFM WBLOWER-120INT (804702) 10" (254 mm) Vertical
W482718, W542718, W602718 or W662718 Remote 900 CFM CTBLOWER-90REM (801641) 10" (254 mm) Vertical
W482718, W542718, W602718 or W662718 Remote 1200 CFM CTBLOWER-120REM (801642) 10" (254 mm) Vertical
W482718, W542718, W602718 or W662718 Remote 1500 CFM CTBLOWER-150REM (804701) 10" (254 mm) Vertical
NOTE: Transition with backdraft damper included.
Wall Hoods – 22" (558 mm) Deep Blower Number Round Duct Discharge
W302210I or W362210I Internal 600 CFM Included (805347) 8" (203 mm) Vertical
W362210, W422210 or W482210 Remote 600 CFM CTBLOWER-60REM (801640) 8" (203 mm) Adjustable
W362210, W422210 or W482210 Remote 900 CFM CTBLOWER-90REM (801641) 8" (203 mm) Adjustable
NOTE: Do not use a 22" (558 mm) deep wall hood with Wolf Dual Fuel Range, Gas Range and Rangetop models with a charbroiler or
griddle.
Transition with backdraft damper included.
Island Hoods Blower Number Round Duct Discharge
I363418, I423418, I543418 or I663418 Internal 1200 CFM IBLOWER-120INT (804703) 10" (254 mm) Vertical
I363418, I423418, I543418 or I663418 Remote 900 CFM CTBLOWER-90REM (801641) 10" (254 mm) Vertical
I363418, I423418, I543418 or I663418 Remote 1200 CFM CTBLOWER-120REM (801642) 10" (254 mm) Vertical
I363418, I423418, I543418 or I663418 Remote 1500 CFM CTBLOWER-150REM (804071) 10" (254 mm) Vertical
NOTE: Transition with backdraft damper included.
Liners (Power Packs) Blower Number Round Duct Discharge
L282212I Internal 600 CFM Included (805347) 8" (203 mm) Vertical
L342212, L402212, L462212, L522212 or L582212
Internal 1200 CFM LBLOWER-120INT (805087) 10" (254 mm) Vertical
L342212, L402212, L462212, L522212 or L582212
Remote 900 CFM CTBLOWER-90REM (804641) 10" (254 mm) Vertical
L342212, L402212, L462212, L522212 or L582212
Remote 1200 CFM CTBLOWER-120REM (801642) 10" (254 mm) Vertical
L342212, L402212, L462212, L522212 or L582212
Remote 1500 CFM CTBLOWER-150REM (804701) 10" (254 mm) Vertical
NOTE: Transition with backdraft damper included.
NOTE: Blower configurations are for reference only. Please refer to minimum CFM recommendations for your specific cooking
product. Always consult a qualified HVAC Engineer for specific applications.