Specifications

51
C OOKTOP V ENTILATION
Electrical Requirements
The Wolf downdraft requires a
separate, grounded 110/120V, 60 Hz
power supply. The service should have
its own 15 amp circuit breaker and a
grounded 3-prong receptacle should
be located within the reach of the 2'
(.6 m) power cord. The specific
location of the outlet is not critical, as
long as it is within reach of the power
cord that is located mid-way, top and
bottom on the right side of the down-
draft.
IMPORTANT NOTE: If the 30" (762
mm) downdraft is being installed in a
30" (762 mm) wide cabinet, or the
36" (914 mm) downdraft in a 36"
(914 mm) wide cabinet, the outlet
cannot be located on the back wall of
the cabinet. The outlet may be placed
in adjacent cabinetry. Refer to the
illustration for placement of electrical.
You must follow all National Electrical
Code regulations. In addition, be
aware of local codes and ordinances
when installing your service.
Wolf downdraft systems have an
adjustable discharge that will allow
you to negotiate ducting around floor
joists and other obstacles. Refer to the
illustration for installation options.
IMPORTANT NOTE: This appliance
must be used with a Wolf approved
top cover and user interface.
The remote mounted user interface is
sold as a sales accessory.
You must plan the installation of the
user interface to be within 10' (3.0 m)
of the downdraft assembly and a
minimum of 4" (102 mm) from the
outer edge of cooktop element or
burner. You will be required to drill
three holes and connect the two units
by the provided wire.
24"min
(610)
36"min (914)
FOR MODEL DD36
30"min (762)
FOR MODEL DD30
E
3
1
/2" (89)
ELECTRICAL
LOCATION IN
ADJACENT RIGHT
SIDE CABINET
NOTE: Dimensions in parentheses are in millimeters.
4"min (102)
10" (254)
E
3
1
/2" (89)
4"min (102)
10" (254)
Electrical placement for downdraft systems
NOTE: DUCT CUTOUT
DIMENSIONS:
10
1
/4
" (260) x 3
1
/2
" (89)
INTERNAL BLOWER
14
1
/4
" (362) x 3
1
/2
" (89)
REMOTE BLOWER
CENTERLINE OF COUNTERTOP CUTOUT
16
3
/8
" (416)
INTERNAL BLOWER
21
1
/2
" (546)
REMOTE BLOWER
5
1
/2
" (140)
INTERNAL BLOWER
4
1
/4
" (108)
REMOTE BLOWER
C
L
22
1
/8
" (562)
INTERNAL BLOWER
19" (483)
REMOTE BLOWER
RIGHT
DISCHARGE
LOCATION
LEFT
DISCHARGE
LOCATION
CENTERLINE OF COUNTERTOP CUTOUT
5
1
/2
" (140)
INTERNAL BLOWER
4
1
/4
" (108)
REMOTE BLOWER
C
L
BOTTOM
DISCHARGE
LOCATION
NOTE: Measurements are to centerline of duct cutouts.
NOTE: Dimensions in parentheses are in millimeters.
5" MAX (127)
REMOTE BLOWER
1" (25) - 7" (178)
INTERNAL BLOWER
2
1
/2
" MAX (165)
REMOTE BLOWER
Adjustable discharge options for downdraft systems