Specifications
48
PLANNING AND
DESIGN INFORMATION
Wolf chimney wall and island hoods
are recommended for use with Wolf
electric, gas and integrated cooktops,
and should be as least as wide as the
cooking surface. These hoods are not
recommended for use with Wolf dual
fuel ranges, gas ranges and rangetops.
Installation of chimney wall and island
hoods should be 24" (610 mm) to 30"
(762 mm) from the bottom of the
hood to the cooking surface.
These hoods are shipped without the
blower assembly. The blower or venti-
lator will vary in size and is always
dictated by the cooking surface and
the distance to the exterior of the
home. The blower assemblies are
quite varied, and depending on the
amount of air you want to move and
the length of the duct run, you have
many options. You also need to
consider if you are going to use these
assemblies as internal blowers or
mount them externally.
Refer to the Cooktop Ventilation
Recommendations charts on pages
58-59 or contact your Wolf dealer for
additional information.
Electrical Requirements
Wolf chimney wall and island hoods
require a separate, grounded 120V,
60 Hz power supply. The service
should have its own 15 amp circuit
breaker. The issue of placing the
outlet is not critical, as long as you
provide a minimum of 6' (1.8 m) of
120V AC power cable.
You must follow all National Electrical
Code regulations. In addition, be
aware of local codes and ordinances
when installing your service.
C OOKTOP V ENTILATION
30" or 35
7
/16"
(762 or 900)
8' to 9'
(2.4 m - 2.7 m)
FLOOR TO
CEILING HEIGHT
48
1
/2" or 50
7
/8"
(1232 or 1292)
MAXIMUM
HEIGHT OF HOOD
30
1
/2" or 32
11
/16"
(775 or 830)
BOTTOM OF HOOD
TO MINIMUM
FLUE EXTENSION
0" to 15
7
/16" or 17
1
/2"
(0 - 392 or 445)
HEIGHT OF
UPPER FLUE
24" to 30"
(610 - 762)
TO COOKING
SURFACE
21"
(533)
E
4"(102)
6"
(152)
NOTE: Dimensions in
parentheses are in millimeters
unless otherwise specified.
42" (1067)
8' to 9'
(2.4 m - 2.7 m)
FLOOR TO
CEILING HEIGHT
47
1
/16" (1195)
MAXIMUM
HEIGHT
OF HOOD
33
9
/16" (853)
BOTTOM OF HOOD
TO MINIMUM
FLUE EXTENSION
0" to 14
7
/16"
(0 - 367)
HEIGHT OF
UPPER FLUE
24" to 30"
(610 - 762)
TO COOKING
SURFACE
27" (686)
LOCATION OF ELECTRICAL
ON CEILING THROUGH
TOP OF HOOD
NOTE: Dimensions in
parentheses are in millimeters
unless otherwise specified.
Installation dimensions for 30" (762 mm) and 36" (914 mm) chimney wall hoods.
Installation dimensions for chimney island hoods.