Specifications
22
PLANNING AND DESIGN
INFORMATION
As with the electric cooktops, you
have three sizes to choose from to
address your clients' needs. The 30"
(762 mm) and 36" (914 mm)
cooktops are available in classic and
platinum stainless steel finish. The 15"
(381 mm) cooktop comes in classic
stainless steel only.
Space Requirements
The illustrations of the three different
size cooktops give you overall dimen-
sions, while the finished cut-out
dimensions you need to incorporate
into your plans are shown in the
illustrations on the following pages.
IMPORTANT NOTE: Wolf gas
cooktops are designed and agency
approved for use with Wolf built-in
ovens only. The cooktop nominal
width must match the built-in oven
nominal width.
IMPORTANT NOTE: When installing
a ventilation hood, refer to the
specific requirements of the hood for
the minimum dimension to cooking
surface.
These cooktops can accommodate
the Wolf downdraft system, a Wolf
chimney or Pro Series ventilation
hood. Refer to pages 46-61 for venti-
lation specifics.
Electrical and Gas Requirements
Wolf gas cooktops are designed to
operate on natural gas at 5" (127
mm) WC (water column) pressure or
LP gas at 10" (254 mm) WC pressure.
They are supplied with a 1/2" (13
mm) NPT male gas connection at the
right rear corner on the bottom of
the cooktop. The male connector
exits the unit straight down and you
are supplied with a regulator with
two female connectors.
4"
(102 mm)
30"
(762 mm)
21"
(533 mm)
4"
(102 mm)
15"
(381 mm)
21"
(533 mm)
36" (914 mm) Gas Cooktop
Model CT36G
30" (762 mm) Gas Cooktop
Model CT30G
15" (381 mm) Gas Cooktop
Model CT15G
4"
(102 mm)
36"
(914 mm)
21"
(533 mm)
W OLF G AS C OOKTOPS
The electric ignition system is a safe,
convenient and reliable manner to
provide ignition for the burners.
However, you need to make provi-
sions for a separate 120V, 60 Hz
power supply. The service should
have its own 15 amp circuit breaker
and a grounded 3-prong receptacle
should be located within the reach of
the 6' (1.8 m) power cord. Refer to
the illustrations on the following
pages.
Wolf gas cooktops using natural gas
function up to an altitude of 8,000'
(2438 m) without any adjustment.
Natural gas installations from 8,000'
(2438 m) to 10,000' (3048 m) need
the High Altitude Kit. Contact your
Wolf dealer for details. LP gas installa-
tions will operate up to 10,000'
(3048 m) without adjustment.
You must follow all National
Electrical Code and gas regulations.
In addition, be aware of local codes
and ordinances when installing your
services.