Specifications

13
PLANNING AND
DESIGN INFORMATION
The Wolf 30" (762 mm) warming
drawer is shipped without any deco-
rative drawer front to the unit. You
must order one of three stainless steel
drawer fronts (handle included) –
classic, platinum or carbon finish or
the integrated front (no handle) for a
custom wood application.
The following illustrations will give
you an idea of the overall size that
you need to plan for in your installa-
tion, plus offer you the finished cut-
out dimensions. Note the combina-
tion installation of a warming drawer
below a 30" (762 mm) oven below a
microwave. Cut-out dimensions and
electrical placement will remain the
same if installed individually.
IMPORTANT NOTE: When installing
the warming drawer above an oven,
include a 2" (51 mm) platform with a
decorative edge, to allow for clear-
ance of overlaps. The platform must
be able to support 175 lbs. (79.4 kg).
This platform must be a minimum of
1" (25 mm) above the kickplate to
allow for the 1/2" (13 mm) overlap of
the warming drawer trim.
W OLF W ARMING D RAWERS
9
1
/4" (235)
ALLOW FOR
5
/8" OVERLAP
ON ALL SIDES
2
3
/8"
(60)
28
1
/2"
(724)
WARMING DRAWER CUT-OUT
23
1
/2"min
(597)
2" x 2" ANTI-TIP
BLOCK AGAINST
REAR OF CUT-OUT
27
3
/16"
(691)
28
1
/2"
(724)
30-INCH OVEN CUT-OUT
5"
(127)
5"
(127)
4"
(102)
4"
(102)
E
E
E
16
1
/2"
(419)
13
1
/2"
(343)
13
3
/4"
(349)
1
1
/4"
(32)
CENTER LINE OF CABINET
27
1
/4"
(692)
MICROWAVE CUT-OUT
24"min
(610)
1
1
/2" (38)
(30" CABINET)
1
1
/4" (32)
(30" CABINET)
NOTE: Dimensions in parentheses are in millimeters.
21"min
(533)
33" (838)
RECOMMENDED CABINET WIDTH
30"min (762)
Installation of a warming drawer below a 30" (762 mm) single oven below a microwave
Electrical Requirements
The warming drawer requires a
separate, grounded 120V, 60 Hz power
supply. The service should have its own
15 amp circuit breaker and a grounded
3-prong receptacle should be located
within the reach of the 3' (.9 m) power
cord, and flush with the back wall.
Please follow the specific space
allocated for the electrical service in
the following illustrations.
You must follow all National Electrical
Code regulations. In addition, be
aware of local codes and ordinances
when installing your service.
29
7
/8"
(759 mm)
23"
(584 mm)
10
1
/4"
(260 mm)
Model WD30
Warming Drawer Overall Dimensions
28
1
/2"(724)
ROUGH
OPENING WIDTH
E
5"
(127)
4"
(102)
23
1
/2"min
(597)
33"(838)
RECOMMENDED CABINET WIDTH
30"min (762)
NOTE: Dimensions in parentheses are in millimeters.
9
1
/4" (235)
2
3
/8" (60)
9
1
/4" (235)
ALLOW FOR
5
/8" OVERLAP
ON ALL SIDES
2
3
/8" (60)
2" x 2" ANTI-TIP
BLOCK AGAINST
REAR OF CUTOUT
RIGHT SIDE
CABINET VIEW
36"(914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
Cut-out dimensions and electrical placement for warming drawer – undercounter application