Specifications
10 
|
 Wolf Customer Care 800.222.7820
WOLF BUILT-IN OVENS
RANGES / RANGETOPSVENTILATION COOKTOPS / COFFEE SYSTEMS OVENS / WARMING DRAWERSOUTDOOR GRILLS
Planning Information
E series ovens can be installed in a standard or ush inset 
application (standard installation only for L series ovens). 
If a cooktop is being installed above an oven, a minimum 
of 
1
/4" (6) is required between units. Location of the elec-
trical supply within the oven opening may require additional 
cabinet depth.
Finish the edges of the opening. They may be visible when 
the door is open.
For standard installations, face trim will overlap stiles and 
rails. Refer to the chart below.
For ush inset installations, a minimum 
1
/4" (6) reveal is 
required on all sides. To ensure consistent reveals, each 
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Single Oven 250 lb (113 kg)
Double Oven 400 lb (181 kg)
TRIM OVERLAP TOP BOTTOM SIDES
30" E Series Oven
1
/2" (13)
1
/8" (3)
11
/16" (17)
30" L Series Oven
1
/8" (3)
1
/8" (3)
11
/16" (17)
36" L Series Oven
3
/16" (5)
1
/8" (3)
9
/16" (14)
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the back wall and 
within the shaded area shown in the illustrations on the 
following pages. For ease of installation, the electrical 
supply for the oven can be placed in an adjacent cabinet 
within reach of the conduit.
Performance may be compromised if the electrical supply is 
less than 240 volts.
The oven is supplied with a conduit consisting of two 
insulated hot lead conductors and a bare ground conductor. 
The wiring diagram covering the control circuit is provided 
with the oven.
ELECTRICAL REQUIREMENTS
SINGLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp dedicated circuit
Conduit 4' (1.2 m), 3' (.9 m) for SO36U
Total Amps 21
Max Connected Load 5.1 kW
Min Supply Wire L1, L2, ground—10 AWG
DOUBLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 50 amp dedicated circuit
Conduit 5' (1.5 m)
Total Amps 37
Max Connected Load 8.9 kW
Min Supply Wire L1, L2, ground—10 AWG