Installation
wolfappliance.com
|
5
Installation Requirements
Follow all minimum clearances to combustible surfaces
shown in the illustration on page 6.
SPECIFICATIONS
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the wall or oor
and within the shaded area shown in the illustration on
page 6. A separate circuit, servicing only this appliance is
required.
If a power supply cord is being used, the cord must be des-
ignated for use with ranges and rated for 240 V, 50 amps,
and must include 3 or 4 conductors. A 4-conductor cord
is required for installations where grounding through the
neutral is prohibited.
Performance may be compromised if the electrical supply is
less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240 VAC, 60 Hz
Service 50 amp dedicated circuit
Rating plate location.
RATING PLATE