Design Guide
88
|
Wolf Customer Care 800.222.7820
Planning Information
MULTIPLE COOKTOPS
When multiple cooktops or modules are installed side
by side, the countertop cut-out dimension is determined by
adding the width of each product plus
1
/4" (6) for each ller
strip, then subtracting 1"
(25). Refer to the chart and illustra-
tion below for typical congurations.
For example, the countertop cut-out for a 30" cooktop and
15" module with one ller strip: 30" + 15" +
1
/4" – 1" = 44
1
/4".
The optional ller strip is avail able through an authorized
Wolf dealer. For local dealer information, visit the nd a
showroom section of our website, wolfappliance.com.
COUNTERTOP CUT-OUT
W
(2) 15" Modules 29
1
/4" (743)
(3) 15" Modules 44
1
/2" (1130)
(4) 15" Modules 59
3
/4" (1518)
30" Cooktop | 15" Module 44
1
/4" (1124)
30" Cooktop | (2) 15" Modules 59
1
/2" (1511)
36" Cooktop | 15" Module 50
1
/4" (1276)
INTEGRATED MODULES
2
1
/2"
(64) min
19
1
/4"
(489)
CUT- OUT
DEPTH
W
CUT-OUT
WIDTH
FRONT OF COUNTERTOP
2" (51) min
Countertop cut-out.
IMPORTANT NOTE: Wolf does not recommend the use
of downdraft ventilation with the grill, steamer or fryer
modules.
Refer to the illustrations on the following pages for instal-
lation of integrated modules. For additional induction and
electric modules, refer to the previous cooktop sections.
VENTILATION OUTDOOR GRILLS RANGES | RANGETOPS COOKTOPS | COFFEE BUILT-IN OVENS