SEALED BURNER RANGETOPS INSTALLATION INSTRUCTIONS Rangetop series ICBSRT Models ICBSRT304 ICBSRT364C ICBSRT364G ICBSRT486C ICBSRT486G ICBSRT484CG ICBSRT484F
ENGLISH 4 3
C O N TA C T I N F O R M AT I O N Website: wolfappliance.com As you follow these instructions, you will noticeWARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed.
W O L F S E A L E D B U R N E R R A N G E TO P I N S TA L L AT I O N R E Q U I R E M E N T S WHAT TO DO IF YOU SMELL GAS: This appliance shall be installed in accordance with the regulations in force and only used in a well ventilated space. Read the instructions before installing or using this appliance. IMPORTANT NOTE: Installation and service must be performed by an authorized person. The appliance must not be modified.
W O L F S E A L E D B U R N E R R A N G E TO P I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer, service agency or gas supplier. R AT I N G P L AT E I N F O R M AT I O N Model Number Serial Number IMPORTANT NOTE: Save these Installation Instructions for the local inspector’s use. Please read the entire Installation Instructions prior to installation.
I N S TA L L AT I O N I N S T R U C T I O N S B E F O R E Y O U S TA R T Check the location where the rangetop will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Do not obstruct the flow of air. The area in which you are installing this appliance must have an adequate supply of fresh air to ensure proper combustion and ventilation. This appliance is not connected to a combustion products evacuation device.
W O L F S E A L E D B U R N E R R A N G E TO P MINIMUM C L E A R A N C E S IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf sealed burner rangetop to avoid fire or damage to adjacent cabinetry or kitchen equipment. Be sure to follow the minimum clearances established in the finished rough opening dimensions. Refer to the Installation Specifications illustration for your model on pages 9– 11 for the exact rough opening dimensions.
I N S TA L L AT I O N I N S T R U C T I O N S 762 mm S E A L E D B U R N E R R A N G E TO P 724 mm OVERALL DEPTH 699 mm 235 mm COOKING SURFACE 445 mm 318 mm 216 mm OVERALL HEIGHT WITH 508 mm RISER WITH WITH 254 mm RISER 127 mm RISER 191 mm 616 mm 759 mm OVERALL WIDTH OVERALL DIMENSIONS Overall Width 759 mm Overall Height (to cooking surface) 216 mm Overall Depth 724 mm Opening Width 762 mm Dimensions may vary to ± 3 mm.
W O L F S E A L E D B U R N E R R A N G E TO P 914 mm S E A L E D B U R N E R R A N G E TO P 724 mm OVERALL DEPTH Overall Width 699 mm 235 mm OVERALL DIMENSIONS 911 mm Overall Height (to cooking surface) 216 mm Overall Depth 724 mm Opening Width 914 mm 445 mm COOKING SURFACE 216 mm OVERALL HEIGHT WITH 508 mm RISER WITH 254 mm RISER 191 mm 911 mm 616 mm OVERALL WIDTH Dimensions may vary to ± 3 mm.
I N S TA L L AT I O N I N S T R U C T I O N S 1219 mm S E A L E D B U R N E R R A N G E TO P 724 mm OVERALL DEPTH 699 mm 235 mm COOKING SURFACE 318 mm 216 mm OVERALL HEIGHT Overall Width WITH WITH 254 mm RISER 127 mm RISER 191 mm 1216 mm 445 mm OVERALL DIMENSIONS WITH 508 mm RISER 616 mm Overall Height (to cooking surface) 216 mm Overall Depth 724 mm Opening Width OVERALL WIDTH 1216 mm 1219 mm Dimensions may vary to ± 3 mm.
W O L F S E A L E D B U R N E R R A N G E TO P I N S TA L L T H E R A N G E T O P I M P O R TA N T N OT E This installation must conform with local codes and ordinances. Prepare the finished rough opening for the rangetop according to the Installation Specifications illustration for your model on pages 9–11. The platform must be 19 mm thick and include a cut-out at the right rear for gas supply and electrical connections.
I N S TA L L AT I ON I N S T R U C T I O N S SAI GLOBAL AS4551 Made in USA Model No: ICBSRT364C Serial No: Gas type Test point press. (kPa) Injector sizes (mm) RHF RHR Grill LHF LHR SAI GLOBAL AS4551 Made in USA LPG 2.75 1.80 1.80 1.78 1.80 1.35 1.09 1.09 1.09 1.09 0.89 Total Consumption (MJ/h) 66.0 Electrical compliance: in accordance with AS/NZS3100 240 V AC, 10 amps, 50 Hz 66.1 Gas type Test point press. (kPa) Injector sizes (mm) RHF RHR Griddle LHF LHR NG 1.0 LPG 2.75 1.80 1.80 1.70 1.
W O L F S E A L E D B U R N E R R A N G E TO P G A S S U P P LY R E Q U I R E M E N T S GAS LEAK TESTING Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections will indicate a leak. If a leak appears, shut off the gas valve and adjust connections. Then check connections again. Clean all the detergent solution from the rangetop. 14 Never test for a gas leak with a match or other flame.
I N S TA L L AT I O N I N S T R U C T I O N S ELECTRICAL R E Q U I R E M E N T S R E C O M M E N D E D G RO U N D M E T H O D ELECTRICAL SHOCK HAZARD — Plug into a grounded 3-prong adapter. Do not remove ground prong. Do not use an adapter. Failure to follow these instructions can result in electric shock, fire or death. IMPORTANT NOTE: If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
W O L F S E A L E D B U R N E R R A N G E TO P S U R FA C E B U R N E R S S E A L E D R A N G E TO P R E M O V A L INITIAL LIGHTING If it is necessary to remove the sealed rangetop for cleaning or service, shut off the gas supply. Disconnect the gas and electric supply. Remove the mounting brackets on the right and left side of the burner box and remove the sealed rangetop. Reinstall in the reverse order and check the gas connection for leaks.
I N S TA L L AT I O N I N S T R U C T I O N S I F YO U N E E D SERVICE For service in your area, contact either your Wolf dealer or visit the Showroom Locator section of our website, wolfappliance.com to find the regional distributor by country. When calling for service, you will need the sealed rangetop model and serial numbers. Both numbers are listed on the rating plate, located on the underside of the sealed rangetop. Refer to the illustration on page 6 for location of the rating plate.
ICB Sealed Burner Rangetop (ICBSRT) Series Wiring Diagrams WIRING SCHEMATIC Model: ICBSRT304 - This wiring information is provided for use by qualified service personnel only. Disconnect appliance from electrical supply before beginning service. Be sure all grounding devices are connected when service is complete. Failure to observe the above warnings may result in severe electrical shock.
ICB Sealed Burner Rangetop (ICBSRT) Series Wiring Diagrams RIGHT REAR SWITCH SW3 10-BLUE 20-BLK CAPPER CONNECTORS 19-BLK 13-BLUE RIGHT FRONT S4 SPARKER WIRE RIGHT REAR S3 SPARKER WIRE 1-BLK RIGHT FRONT SWITCH SW4 JUMPER 2-WHT N IN L1 IN GROUND 6-ORN 3-GRN/YEL This wiring information is provided for use by qualified service personnel only. Disconnect appliance from electrical supply before beginning service. Be sure all grounding devices are connected when service is complete.
ICB Sealed Burner Rangetop (ICBSRT) Series 21-BLK - 10-BLUE 20-BLK RIGHT FRONT S4 RIGHT REAR SWITCH SW3 CAPPER CONNECTORS SPARKER WIRE RIGHT REAR S3 2-WHT 19-BLK SPARKER WIRE 1-BLK GROUND N IN L1 IN 6-ORN 3-GRN/YEL RIGHT FRONT SWITCH SW4 10 VDC SOLENOID 7-ORN 230 V 50 CYCLES This wiring information is provided for use by qualified service personnel only. Disconnect appliance from electrical supply before beginning service.
WOLF APPLIANCE, INC. P O BOX 44848 MADISON, WI 53744 USA WOLFAPPLIANCE.COM Australian Distributor of Sub-Zero & Wolf 1/151 Barkly Avenue, Burnley Victoria Australia 3121 Telephone. +61 3 9421 0232 Facsimile. +61 3 9421 0242 www.subzerowolf.com.