Specifications

8
W O L F M U LT I - F U N C T I O N C O O K T O P
EXPLOSION HAZARD—
S
ecurely tighten all gas connections.
Failure to do so can result in explosion,
fire or death.
G A S S U P P LY R E Q U I R EM E NT S
The product rating plate, located on the
underside of the cooktop, has informa-
tion on the type of gas that should be
used. If this information does not agree
with the type of gas available, contact
the network operator or gas supplier.
If further information is required please
call:
1300 808 859
IM P ORTAN T
NO T E
This installation
must conform with
local codes and
ordinances.
G A S RATI N G
HGC Electrical Injector Test point
(MJ/hr) rating size pressures
Model (gas) (KW) (mm) (kPa)
ICBIM15/S 24.0 6.66 2.45 1.00
ICBIM15/S-LP 24.0 6.66 1.35 2.75
WOK installation_Mono 1.0:Intl Multi-F CT Install 31/3/10 1:26 PM Page 8