DOWNDRAFT VENTILATION INSTALLATION GUIDE
DOWNDRAFT VENTILATION Contents 2 Downdraft Ventilation 3 Specifications 4 Installation Troubleshooting 6 Important Note Product Information To ensure this product is installed and operated as safely and efficiently as possible, take note of the following types of highlighted information throughout this guide: Important product information including the model and serial number are listed on the product rating plate.
SPECIFICATIONS Installation Requirements Electrical Downdraft For installation with a Wolf cooktop, a minimum 638 mm deep flat countertop is required. Installation must comply with all applicable electrical codes and be properly grounded (earthed). INSTALLATION WITH COOKTOP For installation with a sealed burner rangetop, an accessory trim kit is required. Contact your authorized Wolf dealer for details. Locate the electrical supply as shown in the illustrations on pages 3–4.
SPECIFICATIONS INSTALLATION Downdraft Installation INSTALLATION WITH SEALED BURNER RANGETOP W DOWNDRAFT CUT-OUT WIDTH 68 mm E 210 mm* DOWNDRAFT TRANSITION 1 Install or internal blowers, remove the existing 254 mm round F transition. Refer to the illustration below. 2 Install For remote blowers being discharged from the front, leave the 254 mm round transition in place. the top mounting brackets using the #4 sheet metal screws provided. Refer to the illustration below.
INSTALLATION Installation INTERNAL BLOWER o mount the internal blower on the front or rear of the T downdraft: 1 Rotate the blower box so the 152 mm round discharge is properly located, then disconnect the cable from the downdraft receptacle and connect it to the blower receptacle. Refer to the illustrations below. 2 Once the blower connection is made and the discharge properly located, secure the blower to the downdraft using the four screws provided.
INSTALLATION Installation Troubleshooting CONTROL MODULE 1 TOP COVER se the template provided on page 7 to mark holes for U mounting screws. Drill one 40 mm in the center and two 10 mm holes for the mounting screws. CAUTION Verify the scale of the template if not using the installation guide shipped with the downdraft. 2 Check countertop thickness to make sure threaded studs are long enough to allow thumbnuts to fully engage.
CONTROL MODULE TEMPLATE 21 mm 21 mm 65 mm 65 mm CL CL 65 mm 65 mm 21 mm 21 mm CL 0 CL 0 25 mm SCALE 25 mm Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, and Ingredients are registered trademarks and service marks of Sub-Zero, Inc.
WOLF APPLIANCE, INC. PO BOX 44848 MADISON, WI 53744 USA WWW.WOLFAPPLIANCE.