Specifications

5
wolfappliance.com/specs
FLUSH INSET INSTALLATION
A flush inset installation requires the oven to be recessed
into the cabinet. A minimum 635 mm deep cabinet is
needed if you want the front of the oven to be flush with
surrounding cabinetry.
ELECTRICAL REQUIREMENTS
The single and double ovens require a separate, grounded
3-wire 220-240 V AC, 50/60 Hz (Single Phase), or 5-wires
the power inlet box. Refer to the illustration below.
STANDARD INSTALLATION
For ease of installation, Wolf recommends using 838 mm
wide cabinets with 762 mm ovens. You will need a
minimum 610 mm of usable cabinet depth. The cabinet
must be able to support 113 kg for a single oven and 181
kg for a double oven.
The oven has a face trim on all four sides and will overlap
stiles and rails. Refer to the chart for overlap dimensions.
Oven Trim Overlap
Top Overlap 21 mm
Bottom Overlap 3 mm
Side Overlap 19 mm
GRO
Single phase wiring diagram.
N
L1
N
L1
L2
L3
3N
˜
˜
3 phase wiring diagram.
380-415 V AC, 50/60Hz (3 Phase) power supply and uses
E SERIES SINGLE OVENS
Total amps:
Single phase: 19 amps
3phase: 19 amps
E SERIES DOUBLE OVENS
Total amps:
Single phase: 32 amps
3phase: 22 amps