Design Guide

170 | Wolf Customer Care 800.222.7820
PRO VENTILATION
Electrical Requirements
Installation must comply with all applicable electrical codes.
For all Pro hoods except the outdoor wall hood, locate the
electrical supply as shown in the illustrations on the fol-
lowing page. A separate circuit servicing only this appliance
is required.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
OUTDOOR WALL HOOD
Installation must comply with all applicable electrical codes.
For the outdoor wall hood, locate the electrical supply as
shown in the illustrations and chart below. A separate cir-
cuit, servicing only this appliance is required.
A ground fault circuit interrupter (GFCI) is required to reduce
the risk of electrical shock.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
ELECTRICAL KNOCKOUT LOCATION A
36" (914) Outdoor Wall Hood 16" (406)
48" (1219) Outdoor Wall Hood 22" (559)
60" (1524) Outdoor Wall Hood 28" (711)
17"
(432)
A
2
5
/8"
(67)
Electrical knockout location
36" (914) TO 42" (1067) BOTTOM EDGE TO COUNTERTOP
Outdoor wall hood location