E S E R I E S B U I LT - I N O V E N S I NSTALLATION I NSTRUCTIONS
C O N TA C T I N F O R M AT I O N Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions.
W O L F E S E R I E S B U I LT- I N OV E N S I N S TA L L AT I O N R E Q U I R E M E N T S S I T E P R E PA R AT I O N IMPORTANT NOTE: This installation must be completed by a qualified technician. IMPORTANT NOTE: A minimum 24" (610) of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. A minimum 25" (635) of usable cabinet depth is required for a flush inset installation. The electrical box must be flush with the back panel of the cabinet.
W O L F E S E R I E S B U I LT- I N OV E N S E S E R I E S B U I LT- I N S I N G L E OV E N S MODELS SO30-2F/S AND SO30-2U/S IMPORTANT NOTE: A minimum 24" (610) of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. A minimum 25" (635) of usable cabinet depth is required for a flush inset installation. The electrical box must be flush with the back panel of the cabinet.
I N S TA L L AT I O N I N S T R U C T I O N S E S E R I E S B U I LT- I N S I N G L E OV E N S S T A N D A R D I N S TA L L A T I O N C O M B I N AT I O N I N S TA L L AT I O N S IMPORTANT NOTE: For standard installations, a minimum 24" (610) of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. The electrical box must be flush with the back panel of the cabinet.
W O L F E S E R I E S B U I LT- I N OV E N S E S E R I E S B U I LT- I N S I N G L E OV E N S S T A N D A R D I N S TA L L AT I O N Overall Oven Width 29 7/8" (759) Minimum Cabinet Width 30" (762) Overall Oven Height 27 7/8" (708) Minimum Cabinet (Opening) Depth 24" (610) Overall Oven Depth (behind frame) 23 3/4" (603) Opening Width 28 1/2" (724) Open Door Clearance 22" (559) Opening Height 27 3/16" (691) Recommended Cabinet Width 33" (838) Minimum Base Support 250 lbs (113 kg) S T A
I N S TA L L AT I O N I N S T R U C T I O N S E S E R I E S B U I LT- I N S I N G L E OV E N S F L U S H I N S E T I N S TA L L AT I O N Overall Oven Width 29 7/8" (759) Minimum Cabinet Width 33" (838) Overall Oven Height 27 7/8" (708) Minimum Flush Inset Depth 25" (635) Overall Oven Depth (behind frame) 23 3/4" Opening Width 28 1/2" (724) Minimum Flush Inset Width 30 3/8" (772) Open Door Clearance (603) 22" (559) Minimum Base Support 250 lbs (113 kg) 27 3/16" (691) Opening Height Mini
W O L F E S E R I E S B U I LT- I N OV E N S E S E R I E S B U I LT- I N D O U B L E OV E N S MODELS DO30-2F/S AND DO30-2U/S IMPORTANT NOTE: A minimum 24" (610) of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. A minimum 25" (635) of usable cabinet depth is required for a flush inset installation. The electrical box must be flush with the back panel of the cabinet.
I N S TA L L AT I O N I N S T R U C T I O N S E S E R I E S B U I LT- I N D O U B L E OV E N S S T A N D A R D I N S TA L L A T I O N F L U S H I N S E T I N S TA L L AT I O N IMPORTANT NOTE: For standard installations, a minimum 24" (610) of usable cabinet depth is required, or the back panel of the cabinet may need to be removed for proper installation. The electrical box must be flush with the back panel of the cabinet.
W O L F E S E R I E S B U I LT- I N OV E N S E S E R I E S B U I LT- I N D O U B L E OV E N S S T A N D A R D I N S TA L L AT I O N Overall Oven Width 29 7/8" (759) Overall Oven Height 50 3/8" (1292) Minimum Cabinet Width 30" (762) Minimum Cabinet (Opening) Depth 24" (610) (603) Opening Width 28 1/2" (724) Open Door Clearance 22" (559) Opening Height 49 5/8" (1260) Recommended Cabinet Width 33" (838) Minimum Base Support Overall Oven Depth (behind frame) 23 3/4" 400 lbs (181 kg) S T A
I N S TA L L AT I O N I N S T R U C T I O N S E S E R I E S B U I LT- I N D O U B L E OV E N S F L U S H I N S E T I N S TA L L AT I O N Overall Oven Width 29 7/8" (759) Overall Oven Height 50 3/8" (1292) Overall Oven Depth (behind frame) Open Door Clearance 23 3/4" (603) 22" (559) Minimum Base Support 400 lbs (181 kg) Minimum Cabinet Width 33" (838) Minimum Flush Inset Depth 25" (635) Opening Width 28 1/2" (724) Minimum Flush Inset Width 30 3/8" (772) 49 5/8" (1260) Opening Height Minim
W O L F E S E R I E S B U I LT- I N OV E N S S TA N DA R D I N S TA L L AT I O N O P T I O N S E S E R I E S B U I L T- I N S I N G L E O V E N The Wolf E Series single oven may be installed in combination with a Wolf convection or nonconvection microwave oven with 30" (762) E Series trim kit, and a Wolf warming drawer with E Series stainless steel drawer front or integrated drawer front. Refer to the illustration below, and pages 4–7 for installation specifications for E Series single ovens.
I N S TA L L AT I O N I N S T R U C T I O N S S TA N DA R D I N S TA L L AT I O N O P T I O N S E S E R I E S B U I L T- I N D O U B L E O V E N The Wolf E Series double oven may be installed in combination with a Wolf warming drawer with E Series stainless steel drawer front or integrated drawer front. Refer to the illustration below, and pages 8–11 for installation specifications for E Series double ovens.
W O L F E S E R I E S B U I LT- I N OV E N S ELECTRICAL R E Q U I R E M E N T S Verify that power is disconnected from the electrical box before proceeding. I M P O R TA N T N OT E You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. E SERIES SINGLE OVENS Required power supply: 240/208 V AC / 60 Hz / 30 amp service Maximum connected load: 5.1 kW at 240 V AC; 3.
I N S TA L L AT I O N I N S T R U C T I O N S ELECTRICAL R E Q U I R E M E N T S I N S TA L L I N G T H E O V E N With the oven positioned directly in front of the cabinet opening, feed the conduit through the opening in the cabinet platform (where applicable). Then, depending upon local codes, utilize one of the following techniques to connect the appliance to the electrical power supply.
W O L F E S E R I E S B U I LT- I N OV E N S I N S TA L L I N G T H E O V E N O V E N D O O R R E M O VA L To reduce the weight of the oven and ease installation, removal of the oven door(s) is an option. To Remove Oven Door: POSITION THE OVEN The oven is very heavy—use caution when lifting. It is recommended that two people lift and position the oven into the opening. Wear gloves to protect hands from any sharp edges. Open oven door all the way. Flip up the hinge latch on each side.
I N S TA L L AT I O N I N S T R U C T I O N S I N S TA L L I N G T H E O V E N M O U N T O V E N T O C A B I N E T RY O V E N O P E R AT I O N Once the oven is fully inserted into the cabinet opening, locate the mounting holes on the oven side trim. There will be four mounting holes for a single oven and six for a double oven. Refer to the illustration below. Use a 1/16" drill bit to drill pilot holes into the cabinet.
W O L F E S E R I E S B U I LT- I N OV E N S TROUBLES H O OT I N G C O N TA C T I N F O R M AT I O N Wolf Customer Service: 800-332-9513 Website: wolfappliance.com IMPORTANT NOTE: If the built-in oven does not operate properly, follow these troubleshooting steps: If service is necessary, maintain the quality built into your built-in oven by calling a Wolf authorized service center. Verify that power is being supplied to the oven.
The information and images in this book are the copyright property of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc. ©Wolf Appliance, Inc. all rights reserved.
WOLF APPLIANCE, INC. 811576 7 / 2007 P. O . B O X 4 4 8 4 8 MADISON, WI 53744 800-332-9513 W O L FA P P L I A N C E .