Design Guide
wolfappliance.com | 9
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes. 
Locate the electrical supply flush with the back wall and 
within the shaded area shown in the illustrations on the 
following pages. For ease of installation, the electrical 
supply for the oven can be placed in an adjacent cabinet 
within reach of the conduit.
Performance may be compromised if the electrical supply 
is less than 240 volts.
The oven is supplied with a conduit consisting of two 
insulated hot lead conductors and a bare ground con-
ductor. The wiring diagram covering the control circuit is 
provided with the oven.
ELECTRICAL REQUIREMENTS—SINGLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp dedicated circuit
Conduit 4' (1.2 m)
Total Amps 22
Max Connected Load 5.4 kW
ELECTRICAL REQUIREMENTS —DOUBLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 50 amp dedicated circuit
Conduit 5' (1.5 m)
Total Amps 45
Max Connected Load 10.8 kW
Planning Information
The M series oven can be installed in a standard or flush 
inset application. If a cooktop is installed above an oven, a 
minimum of ⁄" 
(6) is required between the units. The loca-
tion of the electrical supply within the oven opening may 
require additional cabinet depth.
Finish the edges of the opening. They may be visible when 
the door is open.
For standard installations, the face trim will overlap stiles 
and rails. Refer to the chart below.
For flush inset installations, a minimum ⁄" 
(3) reveal is 
required on all sides. To ensure consistent reveals, each 
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Single Oven 250 lb (115 kg)
Double Oven 400 lb (181 kg)
TRIM OVERLAP
Top 1" (25)
Bottom 0" (0)
Sides ⁄" (18)
DUAL INSTALLATION
Two M series single ovens can be installed side by side in a 
standard or flush inset application. A dual installation kit is 
required. To maintain appropriate airflow, the ovens must 
be installed into one opening. Any cosmetic or structural 
material placed between the ovens will impede airflow and 
is not recommended. Refer to the illustrations on pages 
14–15.
The dual installation kit is available through an authorized 
Wolf dealer. For local dealer information, visit the find a 
showroom section of our website, wolfappliance.com. 
M Series Ovens