Design Guide
wolfappliance.com | 39
Planning Information
The speed oven can be installed in a standard or flush inset 
application.
Finish the edges of the opening. They may be visible when 
the door is open.
For standard installations, the face trim will overlap stiles 
and rails. Refer to the chart below.
For flush inset installations, a minimum ⁄" 
(3) reveal is 
required on all sides. To ensure consistent reveals, each 
corner of the opening must be exactly 90°.
If the speed oven is installed above or below a Wolf E 
series oven in a flush inset application, a ⁄" 
(6) reveal is 
required.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
24" (610) Model 125 lb (57 kg)
30" (762) Model 125 lb (57 kg)
TRIM OVERLAP 24" MODEL 30" MODEL
Top ⁄" (5) ⁄" (5)
Bottom 0" (0) 0" (0)
Sides ⁄" (18)  3⁄" (98)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on 
the following pages. The receptacle may also be located 
in an adjacent cabinet within reach of the power cord. A 
separate circuit, servicing only this appliance is required. A 
ground fault circuit interrupter (GFCI) is not recommended 
and may cause interruption of operation. Refer to the illus-
tration below for minimum power cord plug clearance.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle NEMA 6-20R grounding type
Power Cord 6' (1.8 m)
NEMA
PLUG
GROUNDED
NEMA RECEPTACLE
1" (25)
MINIMUM
CORD
CLEARANCE
NEMA 6-20R receptacle
Power cord clearance
Speed Ovens