Design Guide
68 
|
 Wolf Customer Care 800.222.7820
Planning Information
Refer to the illustrations on the following pages for instal-
lation of integrated modules. For induction and electric 
modules, refer to the previous cooktop sections. 
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on 
the following pages. A separate circuit, servicing only this 
appliance is required.
When multiple cooktops or modules are installed side by 
side, each must have its own separate electrical supply.
ELECTRICAL REQUIREMENTS
ELECTRIC MODULES
Electrical Supply grounded 3-wire, 240/208 VAC, 60 Hz
Steamer, Fryer 15 amp dedicated circuit
Induction, Electric, Grill 20 amp dedicated circuit
Conduit exible 4'
 (1.2 m)
GAS MODULES
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6'
 (1.8 m)
WOLF INTEGRATED MODULES
DRAIN OUTLET
Steamer and fryer modules require a method for draining 
hot water and oil. For the steamer module, options include 
connecting a drain hose from the 
5
/8" (16) outlet tied into 
an existing drain, a separate drain with freefall or placing a 
heat-resistant receptacle under the drain outlet. For the fryer 
module, the drain outlet must be accessible to drain oil into 
heat-resistant receptacle. 
VENTILATION OUTDOOR GRILLS RANGES / RANGETOPS COOKTOPS / COFFEE SYSTEMS OVENS / WARMING DRAWERS