Design Guide
62  |  Wolf Customer Care 800.222.7820
Planning Information
The warming drawer must be installed with a Wolf drawer 
front, avail able through an authorized Wolf dealer. For 
local dealer information, visit the find a showroom section 
of our website, wolfappliance.com. Specific installation 
instructions are included with the drawer front.
The warming drawer can be installed in a standard or flush 
inset application.
For a standard installation, the drawer collar and front 
panel sit proud of the cabinet face frame. A recessed 
installation requires the cabinetry be recessed by ⁄" 
(5) 
so the collar is flush with the cabinet face frame but the 
drawer front will sit proud. A flush inset installation requires 
the drawer collar and front panel be recessed to be flush 
with surrounding cabinetry. Refer to illustrations on the 
following pages for minimum cabinet dimensions for your 
specific installation.
Finish the edges of the opening. They may be visible when 
the drawer is open.
For standard installations, the face trim will overlap stiles 
and rails. Refer to the chart below.
For flush inset installations, a minimum ⁄" 
(3) reveal is 
required on all sides. To ensure consistent reveals, each 
corner of the opening must be exactly 90°.
Model WWD30O is CSA approved for outdoor installations.
INSTALLATION REQUIREMENTS
Min Base Support 200 lb (90 kg)
Trim Overlap (top, bottom, sides) ⁄" (16)
Warming Drawers