If a cooktop is being installed above an oven, a minimum 
of ⁄" 
(6) is required between the units. The location of 
the electrical supply within the oven opening may require 
additional cabinet depth.
Finish the edges of the opening. They may be visible when 
the door is open.
For standard installations, the face trim will overlap stiles 
and rails. Refer to the chart below.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
36" Single Oven 250 lb (113 kg)
TRIM OVERLAP
Top ⁄" (5)
Bottom ⁄" (3)
Sides ⁄" (14)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and 
within the shaded area shown in the illustration on the fol-
lowing page. For ease of installation, the electrical supply 
for the oven can be placed in an adjacent cabinet within 
reach of the conduit.
Performance may be compromised if the electrical supply 
is less than 240 volts.
The oven is supplied with a conduit consisting of two 
insulated hot lead conductors and a bare ground con-
ductor. The wiring diagram covering the control circuit is 
provided with the oven.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp dedicated circuit
Conduit 3' (.9 m)
Total Amps 21
Max Connected Load 5.1 kW