Design Guide
152  |  Wolf Customer Care 800.222.7820
Planning Information
Pro ventilation hoods and hood liners are recommended 
for use with all Wolf cooking appliances. Wall hoods should 
be at least as wide as the cooking surface and island hoods 
should be 3" 
(76) wider on each side.
For optimal performance in wall hood applications, a pro 
27" deep wall hood is recommended for use with ranges 
and rangetops with a charbroiler or griddle. 
Installation of all Pro hoods except the outdoor wall hood 
should be 30" 
(762) to 36" (914) from the bottom of the 
hood to the countertop. Installation of the outdoor wall 
hood should be 36" 
(914) to 42" (1067) from the bottom of 
the hood to the countertop.
Pro hoods and hood liners are shipped without a blower 
assembly. Internal, in-line, and remote blowers are avail-
able through an authorized Wolf dealer. For local dealer 
information, visit the find a showroom section of our 
website, wolfappliance.com. The blower will vary in size 
and is dictated by the cooking unit, volume of air, and 
length of the duct run. Refer to Ventilation Suggestions on 
pages 154–157.
Pro hoods accommodate a 10" 
(254) round duct. Low-
profile wall hoods allow for an adjustable discharge. All 
other pro hoods have a vertical discharge. For the 24" and 
27" deep wall hoods, a horizontal discharge kit is available 
through an authorized Wolf dealer.
Consult a qualified HVAC professional for specific installa-
tion and ducting applications.
Optional stainless steel duct covers in a variety of heights 
are available for pro wall and island hoods through an 
authorized Wolf dealer.
RECIRCULATING APPLICATION
Low-profile, 24" deep, and 27" deep wall hoods with an 
internal blower 
(600 CFM or less), 30" (762) and 36" (914) 
widths only, can be used in a non-ducted application with 
a recirculating filter. In this installation, kitchen air is puri-
fied through the filters and returned as clean air into the 
room. A recirculation kit, available through an authorized 
Wolf dealer, is required. 
CUSTOM HOOD APPLICATIONS
Wolf pro hood liners are for use in custom hood applica-
tions. The decorative hood can be created out of wood, 
plaster, tile, or metal. The shape of the hood is not critical, 
however, the bottom of the hood and liner must be on 
the same plane. The height of the liner does not need to 
accommodate the entire height of the decorative hood. 
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations 
on the following page. A separate circuit servicing only this 
appliance is required.
For the outdoor wall hood, a ground fault circuit inter-
rupter (GFCI) is required to reduce the risk of electrical 
shock.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Pro Ventilation Hoods