installation guide
4
|
Wolf Customer Care 800.222.7820
Installation Requirements
For installation with a Wolf cooktop, a minimum 25
1
/8" (638)
deep at countertop is required.
For installation with a sealed burner rangetop or 30"
(762)
or 36"
(914) contemporary cooktop, an accessory trim kit is
required and available through an authorized Wolf dealer.
For local dealer information, visit the nd a showroom sec-
tion of our website, wolfappliance.com.
The remote-mounted control module can be positioned
horizontally or vertically. It must be located within 9'
(2.7 m)
of the downdraft assembly and a minimum 3"
(76) from the
edge of the cooktop cutout.
Consult a qualied HVAC professional for specic installa-
tion and ducting applications.
BLOWERS
CAUTION
For use with a Wolf 600 CFM internal blower and
remote blowers rated maximum 3 amps.
Internal, in-line, and remote blowers are available through an
authorized Wolf dealer.
Internal blowers have a 6"
(152) round discharge, can be
front or rear mounted, and can be discharged in any direc-
tion by rotating the blower box. In-line and remote blowers
have a 10"
(254) discharge and can be discharged from the
front or rear.
SPECIFICATIONS
DUCTWORK
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
Wolf downdrafts must be vented outside.
The downdraft operates most efciently with the fewest
number of elbows and transitions and when the ductwork
does not exceed 40'
(12 m).